| Electronic Components Datasheet Search |
|
ITMS4037 Datasheet(PDF) 13 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
ITMS4037 Datasheet(HTML) 13 Page - Red Lion Controls. Inc |
|
13 / 16 page ![]() 13 ALARM 1 (40018) & 2 (40014) ACTION REGISTER TABLE INPUT TYPE REGISTER (40008) TABLE SENSOR FAILURE ACTION REGISTER (40022) TABLE FOR ALARM STATE CONDITION USER INPUT ACTION REGISTER (40013) TABLE Examples: Alarm 1 (40018): Stand-by off, Latch on = 0 0 0 1 <1 > Absolute Lo, Balanced = 0 0 1 0 < 2> <1 2> Alarm 2 (40014): Stand-by on, Latch off = 0 0 1 0 <2 > Band Outside = 0 1 1 1 < 7> <27> COMMUNICATIONS REGISTER (40026) AND COILS 1-8 TABLE * When reading register 40026, B7 will be a 0. When writing (changing ITMS communications to the new setting), change B7 to a 1. Mode Parity Baud Coil 8 B7* Coil 7 B6 Coil 6 B5 Coil 5 B4 Coil 4 B3 Coil 3 B2 Coil 2 B1 Coil 1 B0 Coil 8 =0 HEX Coil 8 =1 HEX RTU 8N1,2 300 0 / 1 0 1 0 0 0 0 0 <20> <A0> RTU 8N1,2 600 0 / 1 0 1 0 0 0 0 1 <21> <A1> RTU 8N1,2 1200 0 / 1 0 1 0 0 0 1 0 <22> <A2> RTU 8N1,2 2400 0 / 1 0 1 0 0 0 1 1 <23> <A3> RTU 8N1,2 4800 0 / 1 0 1 0 0 1 0 0 <24> <A4> RTU 8N1,2 9600 0 / 1 0 1 0 0 1 0 1 <25> <A5> RTU 8N1,2 19200 0 / 1 0 1 0 0 1 1 0 <26> <A6> RTU 8N1,2 38400 0 / 1 0 1 0 0 1 1 1 <27> <A7> RTU 8E1 300 0 / 1 0 1 0 1 0 0 0 <28> <A8> RTU 8E1 600 0 / 1 0 1 0 1 0 0 1 <29> <A9> RTU 8E1 1200 0 / 1 0 1 0 1 0 1 0 <2A> <AA> RTU 8E1 2400 0 / 1 0 1 0 1 0 1 1 <2B> <AB> RTU 8E1 4800 0 / 1 0 1 0 1 1 0 0 <2C> <AC> RTU 8E1 9600 0 / 1 0 1 0 1 1 0 1 <2D> <AD> RTU 8E1 19200 0 / 1 0 1 0 1 1 1 0 <2E> <AE> RTU 8E1 38400 0 / 1 0 1 0 1 1 1 1 <2F> <AF> RTU 8O1 300 0 / 1 0 1 1 1 0 0 0 <38> <B8> RTU 8O1 600 0 / 1 0 1 1 1 0 0 1 <39> <B9> RTU 8O1 1200 0 / 1 0 1 1 1 0 1 0 <3A> <BA> RTU 8O1 2400 0 / 1 0 1 1 1 0 1 1 <3B> <BB> RTU 8O1 4800 0 / 1 0 1 1 1 1 0 0 <3C> <BC> RTU 8O1 9600 0 / 1 0 1 1 1 1 0 1 <3D> <BD> RTU 8O1 19200 0 / 1 0 1 1 1 1 1 0 <3E> <BE> RTU 8O1 38400 0 / 1 0 1 1 1 1 1 1 <3F> <BF> Latched Off=Auto 2nd Nibble HEX Stand By B7 B6 B5 off off 0 0 0 0 <0 > off on 0 0 0 1 <1 > on off 0 0 1 0 <2 > on on 0 0 1 1 <3 > B4 < 8> < 7> 0 1 0 1 0 1 1 0 2 2 8 7 Band Inside Band Outside < 6> 0 1 1 0 2 6 Deviation Lo < 5> 1 0 1 0 2 5 Deviation Hi < 4> 0 0 1 0 2 1 4 Absolute Lo, unbalanced < 3> 1 1 0 0 2 1 3 Absolute Hi, unbalanced < 2> 0 1 0 0 2 1 2 Absolute Lo, balanced < 1> 1 0 0 0 2 1 1 Absolute Hi, balanced < 0> 0 0 0 0 2 1 0 Manual 1st Nibble HEX B0 B1 B2 B3 ALARMS MODE ACTION See Setpoint Alarm Figures, Page 5, for illustrations of alarm operation. MODE TYPE MODE TYPE MODE TYPE 0 Tc - T 5 Tc - S 10 RTD - 385 1 Tc - E 6 Tc - B 11 RTD - 392 2 Tc - J 7 Tc - N 12 RTD - 672 3 Tc - K 8 Tc - C 13 LIN Ohms 4 Tc - R 9 LIN mV MODE ACTION ALARM INPUT ACTIVATION <0000> Reset 1 Level (Maintained) <0001> Reset 2 Level (Maintained) <0002> Reset 1 & 2 Level (Maintained) <0003> Set 1 Level (Maintained) <0004> Set 2 Level (Maintained) <0005 Set 1 & 2 Level (Maintained) <0010> Reset 1 Edge (Momentary) <0011> Reset 2 Edge (Momentary) <0012> Reset 1 & 2 Edge (Momentary) <0013> Set 1 Edge (Momentary) <0014> Set 2 Edge (Momentary) <0015> Set 1 & 2 Edge (Momentary) MODE ALARM 1 ALARM 2 0 Off Off 1 On On 2 Off On 3 On Off |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |