4 / 14 page ![]() 4 Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used. Regulatory Information The ACPL-P347/W347 is approved by the following organizations: UL Recognized under UL 1577, component recognition program up to VISO = 3750 VRMS (ACPL-P347) and VISO = 5000 VRMS (ACPL-W347). CSA CSA Component Acceptance Notice #5, File CA 88324 IEC/EN/DIN EN 60747-5-5 (Option 060 Only) Maximum Working Insulation Voltage VIORM = 891Vpeak (ACPL-P347) and VIORM = 1140 Vpeak (ACPL- W347) Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060) Description Symbol ACPL-P347 Option 060 ACPL-W347 Option 060 Unit Installation classification per DIN VDE 0110/39, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 450 Vrms for rated mains voltage ≤ 600 Vrms for rated mains voltage ≤ 1000 Vrms I – IV I – IV I – III I – III I – IV I – IV I – IV I – IV I – III Climatic Classification 40/105/21 40/105/21 Pollution Degree (DIN VDE 0110/39) 2 2 Maximum Working Insulation Voltage VIORM 891 1140 VPEAK Input to Output Test Voltage, Method b* VIORM x 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC VPR 1671 2137 VPEAK Input to Output Test Voltage, Method a* VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC VPR 1426 1824 VPEAK Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec) VIOTM 6000 8000 VPEAK Safety-limiting values – maximum values allowed in the event of a failure Case Temperature Input Current Output Power TS IS, INPUT PS, OUTPUT 175 230 600 175 230 600 °C mA mW Insulation Resistance at TS, VIO = 500 V RS >109 >109 Ω * Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Avago Regulatory Guide to Isolation Circuits, AV02-2041EN for a detailed description of Method a and Method b partial discharge test profiles. Note: These optocouplers are suitable for“safe electrical isolation”only within the safety limit data. Maintenance of the safety data shall be ensured by means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |