| Electronic Components Datasheet Search |
|
INA209AIPW Datasheet(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA209AIPW Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 50 page ![]() Power Measurement Peak-Hold Registers INA209 SBOS403B – JUNE 2007 – REVISED MARCH 2009 ......................................................................................................................................................... www.ti.com When the INA209 is in the normal operating mode The Conversion Ready bit clears under these (that is, MODE bits of the Configuration Register are conditions: set to '111'), it continuously converts the shunt 1. Writing to the Configuration Register, except voltage up to the number set in the shunt voltage when configuring the MODE bits for Power Down averaging function (Configuration Register, SADC or ADC off (Disable) modes; bits). The device then converts the bus voltage up to 2. Reading the Status Register; or the number set in the bus voltage averaging 3. Triggering a single-shot conversion with the (Configuration Register, BADC bits). The Mode Convert pin. control in the Configuration Register also permits selecting modes to convert only voltage or current, either continuously or in response to an event (triggered). Current and bus voltage are converted at different points in time, depending on the resolution and All current and power calculations are performed in averaging mode settings. For instance, when the background and do not contribute to conversion configured for 12-bit and 128 sample averaging, up to time; conversion times shown in the Electrical 68ms in time between sampling these two values is Characteristics table can be used to determine the possible. Again, these calculations are performed in actual conversion time. the background and do not add to the overall Power-Down mode reduces the quiescent current conversion time. and turns off current into the INA209 inputs, avoiding any supply drain. Full recovery from Power-Down requires 40 µs. ADC Off mode (set by the Configuration Register, MODE bits) stops all Shunt voltage peak registers hold the lowest and conversions. highest converted reading for the shunt value. The shunt value may be either positive or negative; as a In triggered mode, the external Convert line becomes result, there is a need for a sign bit in either register. active. Convert commands are initiated by taking the For instance, the Shunt Voltage Positive Peak Convert line low for a minimum of 4 µs. The Convert Register in most systems records a positive voltage; line may be connected high when unused. Any in most unidirectional current measurement re-trigger of the Convert line during a conversion is applications, the Shunt Voltage Negative Peak ignored, and the Convert line state is disregarded Register also records a positive voltage. However, until the conversion ends. There are several available certain conditions can occur in normally unidirectional triggered modes; however, all conversions are systems that cause a negative polarity across the performed repeatedly up to the number set in the shunt; these events are recorded in the Shunt Averaging function (Configuration Register, BADC Voltage Negative Peak Register. and SADC bits). Peak-hold registers do not record conditions that If the Convert line is held low, writing any of the trigger a Critical Comparator shutdown. A Critical triggered convert modes into the Configuration Comparator shutdown occurs within 5 µs of detecting Register (even if the desired mode is already a critical condition, while the ADC conversion programmed into the register) triggers a single-shot necessary to record a peak-hold requires 532 µs. conversion. Therefore, a system shutdown removes the fault before the analog-to-digital conversion (ADC) can Although the INA209 can be read at any time, and record it. the data from the last conversion remain available, the Conversion Ready bit (Status Register, CNVR bit) is provided to help co-ordinate one-shot or triggered conversions. The Conversion Ready bit is set after all conversions, averaging, and multiplication operations are complete. 16 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated Product Folder Link(s): INA209 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |