17 / 25 page ![]() STOD13CM Detailed description 024087 Rev 1 17/25 initiated. After around 2 ms the soft-start for the inverting is started. The positive and negative voltage will be under regulation around 13 ms after EN pin is asserted high. 7.7 Undervoltage lockout The undervoltage lockout function prevents improper operation of the STOD13CM when the input voltage is not high enough. When the input voltage is below the UVLO threshold, the device is in shutdown mode. The hysteresis of 50 mV prevents unstable operation when the input voltage is close to the UVLO threshold. 7.8 Overtemperature protection An internal temperature sensor continuously monitors the IC junction temperature. If the IC temperature exceeds 140 °C (typ) the device stops operating. As soon the temperature falls below 125 °C (typ) normal operation is restored. 7.9 Short-circuit protection during soft-start (SSD) During device soft-start on positive output, an internal comparator checks if the panel is damaged. In this case, soft-start is stopped and the device is parked in power-off. To restore to normal functionality (assuming that the anomalous load condition has been removed), it is necessary to restart the converter through an enable transient. In the opposite case (panel not damaged), during soft-start, after positive output startup, a negative output soft-start will follow until normal output functionality and voltages are reached. 7.10 Overload protection (OLP) Output current is internally limited. An overload condition, such as a short-circuit, between the two outputs or between each output and GND induces the device to power off. To restore to normal functionality (assuming that the short condition has been removed), it is necessary to restart the converter through an enable transient. 7.11 Short-circuit protection (SCP) When a short-circuit occurs, the device detects the voltage difference between VIN and VOUT. Overshoots are limited by decreasing the inductor current. After this, the output stages of the device are turned off. This status is maintained, preventing current flowing to the load. A new enable transition is needed to restart the device. During startup, the short- circuit protection is active. 7.12 Fast discharge When ENABLE turns from high to low level, the device goes into shutdown mode; LX1 and LX2 will stop switching. A resistor of about 400 Ω is connected between VMID and VO2 to quickly discharge the CMID and CO2 capacitors, lowering the differential output voltage (VMID-VO2) below 10% of nominal value in about 10 ms. When the output voltages are discharged to 0 V, the switches turn off and the outputs will be high impedance. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |