7 / 12 page ![]() 3974 DMOS DUAL FULL-BRIDGE PWM MOTOR DRIVER 7 www.allegromicro.com V REG. This internally generated supply voltage is used to operate the sink-side DMOS outputs. V REG is internally monitored and in the case of a fault condition, the outputs of the device are disabled. The V REG terminal should be decoupled with a 0.22 µF capacitor to ground. Charge Pump. The charge pump is used to generate a supply voltage greater than V BB to drive the source-side DMOS gates. A 0.22 µF ceramic capacitor should be connected between CP1 and CP2 for pumping purposes. A 0.22 µF ceramic capacitor should be connected between V CP and VBB to act as a reservoir to run the high-side DMOS devices. The CP voltage is inter- nally monitored and in the case of a fault condition, the outputs of the device are disabled. Shutdown. In the event of a fault due to excessive junction temperature, or low voltage on CP or V REG, the outputs of the device are disabled until the fault condition is removed. At power up, or in the event of low V DD, the UVLO circuit disables the drivers and resets the data in the serial port to all zeros. Current Regulation. Load current is regulated by an internal fixed off-time PWM control circuit. When the outputs of the DMOS H-bridge are turned on, the current increases in the motor winding until it reaches a trip value determined by the external sense resistor (R S), the applied analog reference voltage (V REF), and serial data bit D16: When D16 = 0 ....................... I TRIP = VREF/10RS When D16 = 1 ....................... I TRIP = VREF/5RS At the trip point, the sense comparator resets the source-enable latch, turning off the source driver (except in the case of low- side only mode where the sink driver is turned off). The load inductance then causes the current to recirculate for the serial- port programmed fixed off-time period. The current path during recirculation is determined by the configuration of slow/ mixed-decay mode (D17) and the synchronous rectification control bits (D11 and D12). FUNCTIONAL DESCRIPTION (continued) Sleep Mode. The input terminal SLEEP is dedicated to putting the device into a minimum current draw mode. When asserted low, the serial port will be reset to all zeros and all circuits will be disabled. PWM Timer Function. The PWM timer is programmable via the serial port (bits D2 – D10) to provide fixed off-time PWM signals to the control circuitry. In mixed current-decay mode, the first portion of the off time operates in fast decay, until the fast-decay time count is reached (serial bits D7 – D10), fol- lowed by slow decay for the rest of the off-time period (bits D2 – D6). If the fast-decay time is set longer than the off-time, the device effectively operates in fast-decay mode. Bit D17 selects mixed or slow decay. Synchronous Rectification. When a PWM off cycle is triggered, either by an ENABLE chop command or internal fixed off-time cycle, load current will recirculate according to the decay mode selected by the control logic. After a short crossover delay, the A3974 synchronous rectification feature will turn on the appropriate MOSFET (or pair of MOSFETs for the mixed decay portion of the off-time) during the current decay and effectively short out the body diodes with the low r DS(on) driver. This will lower power dissipation significantly and can eliminate the need for external Schottky diodes. Synchronous rectification can be configured in active mode, passive mode, low side only, or disabled via the serial port (bits D11 and D12). The active mode prevents reversal of load current by turning off synchronous rectification when a zero current level is detected. Passive mode will allow reversal of current but will turn off the synchronous rectifier circuit if the load current inversion ramps up to the current limit set by V REF/10RS (when D16 = 0) or VREF/5RS(when D16 = 1). Low side only mode will switch the low-side MOSFETs on during the off time to short out the current path through the MOSFET body diode. With this setting, the high-side MOSFETs will not synchronously rectify so four external diodes from output to supply are recommended. This mode is intended for use with high-power applications where it is desired to save the expense of two external diodes per bridge. In this mode, the sink-side MOSFETs are chopped during the PWM off time. In all other cases, the source-side MOSFETs are chopped in response to a PWM OFF command. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |