| Electronic Components Datasheet Search |
|
EB-ACDC Datasheet(PDF) 4 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
EB-ACDC Datasheet(HTML) 4 Page - List of Unclassifed Manufacturers |
|
4 / 4 page ![]() DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH München, Germany Tel: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025 DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark. DS-0341B 09/02 DMS-EB-AC/DC ® ® 4. DC Current Measurements (Use +/-200mV Range DMS-30-0 Meters): When using R2 location for a dc current-shunt, please note that the pc- board copper traces which short out R1 can only carry currents up to 0.2A (200mA). However, dc currents up to 2A can be accommodated if a 20AWG jumper wire is soldered in location R1. Be sure R2 has a sufficient power rating to safely carry the full load current. Refer to DMS Application Note 6 for more information on dc ammeters. 1. Install R2: R2 = FSR / (IMAX . x 10000) where FSR is the desired meter reading (0 up to 1999, disregarding any decimal points), and IMAX is current in Amperes. 2. Configure the DMS-EB for span adjust using the procedure previously outlined for the DMS-30-0 (+/-200mV range). 3. Apply the input signal (current) to TB1 (+) HI and (–) LO. 4. Adjust R4 for desired full scale readings. 5. Enable the appropriate decimal point using SG1, SG2, or SG3. Example Using a DMS-30-0 meter, a 0.100 Ampere input must read “100.0” mA on the display. R2 = 1000 / (0.1 x 10000) R2 = 1 Ohm Enable DP3 via SG3 for a display reading of “100.0”. www.datel.com ISO 9001 REGISTERED Applications 100-264Vac POWER SUPPLY BOARD FOR DMS-30 METERS Figure 3. R4 and R5 Installation Figure 4. R1 and R2 Installation 12 R3 SG9 SG11 SG6 SG10 SG14 SG7 SG8 SG13 SG4 SG12 TB1 HI(+) LO(–) 1 2 DP4 R5 R4 12 R3 SG9 SG11 SG6 SG14 SG7 SG8 SG13 SG4 SG12 TB1 HI(+) LO(–) 1 2 DP4 R1 R2 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |