2 / 18 page ![]() AN939 DS00939A-page 2 © 2005 Microchip Technology Inc. To get an accurate picture of power consumption for an AC system, we need to make frequent measurements, preferably many times that of the supply frequency. In this application, we use a sampling rate of 400 Hz, which provides 8 samples per full cycle of the line frequency (for AC supply frequency of 50 Hz). For a sampling rate Fs, we get N samples in N/Fs seconds. By multiplying this expression for time by average power, we obtain an expression for energy consumed in terms of wattseconds (the second expression in Equation 1). From here, we can use simple math to calculate kilowatthours. Of course, it is difficult for a microcontroller to make direct measurements when the supply voltage is coming straight off the mains: say, 230V at up to 50A. This makes it necessary to indirectly measure line voltage and current at a level consistent with a micro- controller, then rescale these measurements to arrive at the original value. The best way to do this is to reduce the voltage to a level and dynamic range that is compatible with digital circuitry. (Measuring current here is essentially the same as measuring voltage, in that we will use a transducer that generates a voltage proportional to the load current.) The actual voltage and current readings can then be derived. For this application, the derived voltage reading, Vd, is related to the actual instantaneous line voltage Vi by the expression, Vd = Vi Kd/Kv or Vi = Vd Kv/Kd, where Kd is the digitization constant for the ADC in this applica- tion and Kv is the voltage proportionality constant for the circuit design. For this particular application, Kd is 204.6, the digital value from the ADC that represents 1V. Kv is the factor by which the input line voltage is reduced by a voltage divider; in our design, it is 300. Similarly, the derived current reading, Id, is related to Ii by the expression, Id = Ii Kd/Ki or Ii = Id Ki/Kd, where Ki is the current proportionality constant specific to this design; it is calculated by dividing the CT turn ratio by the product of the current amplifier gain and the input burden resistance. For this application, based on a 5000-turn CT, the value of Ki works out to be approximately 8.7. Kd is the same as before. By substituting the attenuated values of Vd and Id for the Vi and Ii in the original power measurement equation, we get an expression that relates the con- sumed power directly to the indirect voltage and current measurements, as shown in Equation 2. EQUATION 2: CALCULATING CONSUMED ENERGY FROM INDIRECT MEASUREMENTS We could accumulate a running total indefinitely and directly interpret it for energy consumed over time. How- ever, it’s more practical to accumulate up to some fixed amount, then increment a counter to indicate energy consumption. For our application, we will accumulate 10 Wh (0.01 kWh) before incrementing the counter. This value represents the resolution limit of the meter. It is equivalent to 36,000 wattseconds (10 Wh x 60 x 60); this means that we increment the counter every time that the right side of Equation 2 reaches 36,000. We can also rearrange Equation 2 to define the power consumed entirely in terms of Vd and Id. Since we have already defined Fs, Kv, Ki and Kd in constant terms, we can give the whole quotient on the right side of the equation a constant value, D (Equation 3). EQUATION 3: REDEFINING POWER IN TERMS OF Vd AND Id ONLY In simple terms, any time that the accumulated sum of the voltage and current products equals or exceeds D, we increment the kWh counter. We also save any remainder in excess of D to be used in the next round of accumulation. Note that anything which might influence the value of the constants may also affect the value of D and requires changes to the amplifier design. This includes the use of a shunt instead of a CT, or even changing the CT turn ratio, both of which may change Ki. Note: The calculation of Ki when using a shunt is somewhat different. The actual circuit design for current measurement, and the design considerations for using a shunt, are discussed in more detail in “Hardware Design”, starting on page 10. Energy Consumed (wattseconds) = N ΣV d • Id k = 1 Fs • K 2 ⎛ ⎜ ⎝ kk ⎞ ⎟ ⎠ • (Kv • Ki) d When 0.01 kWh is consumed: = N ΣV d • Id k = 1 Kv • Ki kk 3600 • Fs • K 2 d = D |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |