| Electronic Components Datasheet Search |
|
LM8560 Datasheet(PDF) 4 Page - Unisonic Technologies |
|
|
|||||||||||||||||||||||||||||
LM8560 Datasheet(HTML) 4 Page - Unisonic Technologies |
|
4 / 9 page ![]() UTCLM8560 MOS IC UTC UNISONIC TECHNOLOGIES CO., LTD. 4 QW-R502-005,D Table1 Display Modes Selective lnput Alarm Sleep Display Mode Digit No. 1 Digit No. 2 Digit No. 3 Digit No.4 NC NC Time display 10’s place for hour, AM/PM Hour 10’s place for Minute Minute VSS NC Alarm display 10’s place for hour, AM/PM Hour 10’s place for Minute Minute NC VSS Sleep display Clear Hour 10’s place for Minute Minute VSS VSS Second display Clear Minute 10”s place for Second Second Note: Activating VSS using two inputs simultaneously (alarm select and sleep select), the display mode is switched to display seconds. *Time Setting Input: There are two setting inputs for use with “hour” and “minute”. Time content settings show in Table2 are possible by activating VSS to these pins, A pull-down resistor is built-in. Table2 Setting contents Display Mode Set Input Functions Hour Immediately adds 1 to hour digits and then assigns an additional 1, at a speed of 2 Hz, after each 1/4 to 3/4 second. Min Immediately adds 1 to minute digits and then assigns an additional 1, at a speed of 2 Hz, after each 1/4 to 3/4 second. Seconds are rest. Time Both Operates both as outline above. Hour (note1) Second digits are cleared to [00]. Min Time holds. Second (Alarm & Sleep) Both (note2) Resets hour and minute digits as [0:00] when operating in 24-H mode or [12:00] when operating in 12-H mode. Hour Immediately adds 1 to hour digits and then assigns an additional 1, at a speed of 2 Hz, after each 1/4 to 3/4 second. Min Immediately adds 1 to minute digits and then assigns an additional 1, at a speed of 2 Hz, after each 1/4 to 3/4 second. Alarm Both Resets hour and minute digits as [0:00] when operating in 24-hour mode or [12:00] when operating in 12-hour mode. - Sets sleep counter to [0:59] instantly when VDD is activated to sleep select Hour Sets Sleep counter to [1:59] instantly when VDD is activated to sleep select and hour at the same time. Min Sleep counter looses 1 at a speed of 2 Hz. Sleep Both Sleep counter looses 1 at a speed of 2 Hz. Note:1.Once conditions have been switched to reset or hold, input of other functions is locked until both Hour and Min input have been separated. 2.When the digital reading for seconds is between 30 and 59 seconds, 1 is added to the digits for minutes as he digital reading for seconds rests to [00]. *12/24H Select Input : When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables the 24-hour display. A pull-down resistor is build-in. *Power Failure Detection Display : |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |