13 / 20 page ![]() 13 LTC4210-1/LTC4210-2 421012f Circuit Breaker Timer Operation When a current limit fault is encountered at time point A in Figure 5, the circuit breaker timing is activated with a 60 µA pull-up. The circuit breaker trips at time point B if the fault is still present and the TIMER pin voltage reaches the COMP2 threshold and the LTC4210 shuts down. For a continuous fault, the circuit breaker delay is: tV C A CBDELAY TIMER = µ 13 60 .• (13) Intermittent overloads may exceed the current limit as in Figure 6, but if the duration is sufficiently short, the TIMER pin may not reach the COMP2 threshold and the LTC4210 will not shut down. To handle this situation, the TIMER discharges with 2 µA whenever (VCC – SENSE) voltage is below the 50mV limit and the TIMER voltage is between the COMP1 and COMP2 thresholds. When the TIMER voltage falls below the COMP1 threshold, the TIMER pin is discharged with an equivalent 7k resistor (normal mode, 100 µA source) when (VCC – SENSE) voltage is below the 50mV limit. If the TIMER pin does not drop below the COMP1 threshold, any intermittent overload with an ag- gregate duty cycle of more than 3.8% will eventually trip the circuit breaker. Figure 7 shows the circuit breaker response time in seconds normalized to 1 µF. The asym- metric charging and discharging of TIMER is a fair gauge of MOSFET heating. t C sF VF AD A TIMER (/ ) .• •– µ= µ µ () µ 13 1 60 2 (14) When the circuit breaker trips, the GATE pin is pulled low. The TIMER enters latchoff mode with a 5 µA pull-up for the LTC4210-2 (latched-off version), while an autoretry “cool- off” cycle begins with a 2 µA pull-down for the LTC4210-1 (autoretry version). An autoretry cool-off delay of the LTC4210-1 between COMP2 and COMP1 thresholds takes: tV C A COOLOFF TIMER = µ 11 2 .• (15) APPLICATIO S I FOR ATIO VTIMER NORMAL MODE FAULT MODE 100 µA COMP1 CIRCUIT BREAKER TRIPS LATCHED OFF (5 µA PULL-UP) OR RETRY (2 µA PULL-DOWN) COMP2 AB 60 µA 4210 F05 Figure 5. A Continuous Fault Timing OVERLOAD DUTY CYCLE, D (%) 10 30 1 4210 F07 0.01 0.1 20 100 90 80 70 60 50 40 0 (s/ µF) = t CTIMER 1.3V • 1 µF 60 µA • D – 2µA Figure 7. Circuit Breaker Timer Response for Intermittent Overload A1 B1 A2 B2 A3 B3 ~50mV/RSENSE 60 µA CIRCUIT BREAKER TRIPS COMP1 4210 F06 COMP2 ILOAD VTIMER VGATE 2 µA CB FAULT CB FAULT CB FAULT 2 µA LATCHED OFF (5 µA PULL-UP) OR RETRY (2 µA PULL-DOWN) 60 µA 60 µA 10 µA 10 µA Figure 6. Mulitple Intermittent Overcurrent Conditon |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |