  SM3015AX Datasheet HTML 1Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 2Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 3Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 4Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 5Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 6Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 7Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 8Page - SamHop Microelectronics Corp. SM3015AX Datasheet HTML 9Page - SamHop Microelectronics Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 24 page
background image
FUNCTION DESCRIPTION
SM3015 has two control types : panel keypad and infrared remote control.
There are four to eight control signal operations :
* Start-up by SPEED key
a. function turn off (OFF key)
b. wind mode select (MODE key)
c. start-up function and wind speed select (SPEED key)
d. timer setting (TIMER key)
e. swing head or tuner for swing angle (SW1 and SW2 key)
f. lighting control (LIGHT key)
* Start-up by ON/OFF key
a. function control (ON/OFF key)
b. wind mode select (MODE key)
c. wind speed select (SPEED key)
d. timer setting (TIMER key)
e. swing head or tuner for swing angle (SW1 and SW2 key)
f. lighting control (LIGHT key)
All functions can be planned by user like an MCU for more product application.
Only SPEED or ON/OFF key can enable the fan controller, except for the light control. Wind mode,
timer and swing head inputs can not be accepted when fan is not activated. The fan controller will be
turned off by timer and OFF (ON/OFF) key inputs.
When more than one key are pressed, controller will not accept the multi-key's control signal, if the
panel keys are pressed more than six seconds, controller will generate a " BI-BI-BI-BI" warning sound.
When fan is enabled by SPEED or ON/OFF key, the initial state of fan controller is as follows:
* Memory function available
If Fan controller is OFF on sleep mode, all memory functions will be returned to the LAST TURN
ON STATE.
a.Grade as last state but with starting medium wind for three seconds (MASK option)
b. The wind mode as last state except sleep mode
c. Swing function as last state
d. Timer setting off
e. Light is independent
* Non-memory function (Bonding option)
a. Grade is low wind function but with starting medium wind for three seconds (MASK option)
b. Normal wind mode operation
c. Timer setting and swing head off
d. Light is independent
Page 5
V.2.0 Mar 8, 2002
SM3015
SAMHOP Microelectronics Corp.
三合微科股份有限公司
REMOTE FAN MCU



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com