| Electronic Components Datasheet Search |
|
ABC300 Datasheet(PDF) 3 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
ABC300 Datasheet(HTML) 3 Page - Bel Fuse Inc. |
|
3 / 6 page ![]() ABC300 Series 3 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00285_AE PARAMETER DESCRIPTION / CONDITION SPECIFICATION Output Power6, 7 Derate linearly to 80% from 90 VAC to 80 VAC input. 200 to 325 W Efficiency 120 VAC 230 VAC 88% typical 92% typical Hold Up Time 120 / 230 VAC 10 ms Power Factor 120 VAC 230 VAC 0.98 0.95 Line Regulation +/-0.5% Load Regulation +/-2% Transient Response 50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/ μs, < 10%, recovery time < 5 ms Rise Time < 100 ms Set Point Tolerance8 ± 1% Voltage Output Adjustment ± 3 % Over Voltage Protection Automatic recovery 110 to 150 % Over Current Protection 110 to 150 % Short Circuit Protection Short term, automatic recovery Over Temperature Protection Automatic Recovery 110° C primary heat sink PARAMETER DESCRIPTION / CONDITION Power Good9 TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s Remote On/ Off To turn on PSU short remote pin to ground Remote Sense Compensates for 200 mV cable drop Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B 6 Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1% load on main output to be within regulation band. Ripple and noise is less than 10%. 7 The de-rating curves are valid for input voltages of 115VAC to 264 VAC. Below 115 VAC to 90 VAC the convection rating is 180 W max. 8 Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%. 9 Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5 V is 10K. It is recommended to use external transistor if intended to source current. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |