32 / 55 page ![]() XRT7300 áç áç áç áç E3/DS3/STS-1 LINE INTERFACE UNIT REV. 1.1.1 28 Design Considerations for E3 Applications or if the Overall Cable Length is known Figure 18 indicates the following: A. the length of cable between the Transmitting Ter- minal and the Digital Cross-Connect system can range between 0 and 450 feet and B. the length of cable between the Digital Cross- Connect system and the Receive Terminal can range between 0 and 450 feet. The overall cable length between the Transmitting Terminal and the Receiving Terminal can range be- tween very short cable length (near 0 feet) up to 900 feet. If during system installation the overall cable length is known, then (to optimize the performance of the XRT7300 in terms of receive jitter performance, etc.), the Receive Equalizer should be enabled or disabled based upon the following recommendations: The Receive Equalizer should be turned ON if the Receive Section is going to receive a line signal with an overall cable length of 300 feet or greater. The Receive Equalizer should be turned OFF if the Re- ceive Section is going to receive a line signal over a cable length of less than 300 feet. NOTES: 1. If the Receive Equalizer block is turned ON (in a given Receive Section that is receiving a line signal over short cable length), there is the risk of over- equalizing the received line signal which could degrade performance by increasing the amount of jitter that exists in the recovered data and clock sig- nals or by creating bit-errors. 2. The Receive Equalizer has been designed to counter the frequency-dependent cable loss that a line signal experiences as it travels from the Trans- mitting Terminal to the Receiving Terminal. How- ever, Receive Equalizer was not designed to counter flat loss where all of the Fourier frequency components in the line signal are subject to the same amount of attenuation. Flat loss is handled by the AGC block. The Receive Equalizer block can be disabled setting the REQDIS input pin “High” when operating in the Hardware Mode or writing a "1" to the REQDIS bit- field in Command Register CR2 when operating the XRT7300 in the HOST Mode. 3.3 PEAK DETECTOR AND SLICER After the incoming line signal has passed through the Receive Equalizer it is routed to the Slicer block. The purpose of the Slicer is to quantify a given bit-period (or symbol) within the incoming line signal as either a “1” or a “0”. 3.4 CLOCK RECOVERY PLL The output of the Slicer, which is now Dual-Rail digital pulses, is routed to the Clock Recovery PLL. The purpose of the Clock Recovery PLL is to track the in- coming Dual-Rail data stream and to derive and gen- erate a recovered clock signal. It is important to note that the Clock Recovery PLL re- quires a line rate clock signal at the EXCLK input pin. The Clock Recovery PLL operates in one of two modes: • The Training Mode. • The Data/Clock Recovery Mode 1. The Training Mode If the XRT7300 is not receiving a line signal via the RTIP and RRING input pins or if the frequency differ- ence between the line signal and that applied via the EXCLK input pin exceeds 0.5%, then the XRT7300 LIU IC is operating in the Training Mode. When the LIU is operating in the Training Mode it does the fol- lowing: A. declares a Loss of Lock indication by toggling the RLOL output pin “High” and B. outputs a clock signal via the RCLK1 and RCLK2 output pins which is derived from the signal ap- plied to the EXCLK input pin. 2. The Data/Clock Recovery Mode If the frequency difference between the line signal and that applied via the EXCLK input pin is less than 0.5%, the XRT7300 LIU IC is operating in the Data/ Clock Recovery Mode. In this mode, the Clock Re- covery PLL is locked onto the line signal via the RTIP and RRING input pins. 3.5 THE HDB3/B3ZS DECODER The Remote Transmitting Terminal typically encodes the line signal into some sort of Zero Suppression Line Code (e.g., HDB3 for E3 and B3ZS for DS3 and STS-1). The purpose of this encoding activity was to aid in the Clock Recovery process of this data in the Near-End Receiving Terminal. However, once the da- ta has made it across the E3, DS3 or STS-1 Trans- port Medium and has been recovered by the Clock Recovery PLL, it is now necessary to restore the orig- inal content of the data. The purpose of the HDB3/ B3ZS Decoding block is to restore the data (transmit- COMMAND REGISTER CR2 (ADDRESS = 0X02) D4 D3 D2 D1 D0 DECODIS ENCODIS ALOSDIS DLOSDIS REQDIS X0X X 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |