4 / 12 page ![]() sames PM2005M/P 4/12 http://www.sames.co.za http://www.sames.co.za SETTING UP THE MODULE FOR ENERGY MEASUREMENT Figure 3 below shows a typical setup for the PM2005M/P evaluation module. The three phase voltages are connected directly to SK1 and each corresponding phase current is wired through the on-board CT’s. Figure 3 also shows the default jumper settings. The PM2005M/P evaluation module is setup by default for Figure 3: PM2005M/P setup and connection 3x230V/60A operation. For 3x 115V operation jumpers J1, J2 and J3 need to be closed and capacitors C12, C13 and C14 values must be changed to 1µF / 150VAC. As soon as a load is applied, the pulse LED L7 will start flashing and the energy counter will increment proportional to the energy measured. Load SK1 N PH1 PH2 PH3 J1 J2 J3 J7 J6 GND J5 VSS J4 VDD S1 S2 S3 S4 S6 S7 S8 S9 S10 S5 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|