6 / 14 page ![]() http://www.sames.co.za 6/14 PRELIMINARY PM4104APDA SETTING UP THE PM4104APDA The PM4104APDA evaluation board can be set up for the various functionality of the SA4104A/B through jumpers. The function of each jumper is described in Table 2. The connection of the jumpers corresponds to the markings on the evaluation board. Table 2: Jumper functionality for the PM4104APDA Jumper Description J1 Mains Voltage Selection: This jumper is used to select the mains voltage of the system. It should be left open when the mains voltage is 220V and should be closed when 110V mains voltage is used. J2 R0 Selection: This jumper is used to set the value of the R0 pin to VSS (“0”) or to VDD (“1”). J3 R1 Selection: This jumper is used to set the value of the R1 pin to VSS (“0”) or to VDD (“1”). J4 R2 Selection: This jumper is used to set the value of the R2 pin to VSS (“0”) or to VDD (“1”). J5 R3 Selection: This jumper is used to set the value of the R3 pin to VSS (“0”) or to VDD (“1”). J6 FMS Selection: This jumper is used to set the value of the FMS pin to VSS (“0”) or to VDD (“1”). It can also be left open to set FMS to a floating condition to enable FAST mode on the SA4104A/B. J8 LED Enable: This jumper can be used to disable the pulse output of the evaluation board. Leaving it open will disable the PULSE LED as well as the PULSE opto-isolated output (JS5). J10 DIR Enable: This jumper can be used to disable the direction output of the evaluation board. Leaving it open will disable the DIR LED. J12, J13 Counter Enable: These jumpers can be used to disable and configure the external energy counter that is connected to the COUNTER output (JS4). Leaving both jumpers open disconnects the counter from the energy metering device. Closing J12 and setting J13 to “A” configures the COUNTER output to accommodate a stepper motor counter by connecting the COUNTER terminal to MON and MOP of the energy metering device. Closing J12 and setting J13 to “B” configures the COUNTER output to accommodate an impulse counter by connecting the COUNTER terminal to MON of the energy metering device and VSS. J1 PM4104APDA 1 J6 0 1 J2 0 1 J3 0 1 J4 0 0 J5 1 J12 J13 A B J8 J10 J1 PM4104APDA 1 J6 0 1 J2 0 1 J3 0 1 J4 0 0 J5 1 J12 J13 A B J8 J10 Figure 5: Layout of jumpers on the PM4104APDA |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |