10 / 15 page ![]() SPEC-1081 (REV. 2) 10/15 29-09-2017 SA4101A Direction Select Input (DIRI) Depending on the state of the DIRI pin the energy to be measured can be in the positive direction only, in the negative direction only, or in both directions. Connecting DIRI to VDD will result in energy only being measured in the positive direction. Energy flowing in the negative direction will not be measured. Connecting DIRI to VSS will result in energy only being measured in the negative direction. Energy flowing in the positive direction will not be measured. Connecting the DIRI pin to the DIRO output pin enables bidirectional mode where energy is measured regardless of direction. OUTPUT SIGNALS Motor pulse output (MOP, MON) The MOP and MON pins are complimentary outputs with a frequency proportional to the average power consumption measured. These outputs can be used to either directly drive a stepper motor counter or an electro-mechanical impulse counter. The Rated Conditions Select pins (R0, R1 and R2) allow the selection of different output frequencies corresponding to different meter constants. Figure 8 indicates the timing of these signals. t1 = t2 = t3 = 213ms t4 is proportional to the average power and can be calculated using Equation 2 and the motor output constants in Table 2. Figure 8: Motor outputs MON and MOP LED Output (LED) The LED output pin provides a pulse output with a frequency proportional to the average energy when in STANDARD mode and the instantaneous energy when in FAST mode. This output is primarily used for calibration purposes. The Rated Conditions Select pins (R2, R1 and R0) allow different frequencies to be selected. The LED output is active low. Figure 9 shows the LED waveform when in STANDARD mode. t1 = 90ms t2 is proportional to the average power and can be calculated using Equation 1 along with the appropriate LED output constant in Table 1. Figure 9: LED pulse output in STANDARD mode In FAST mode the LED pulse output is set at a high frequency of 1160Hz at IMAX and VNOM. This mode is useful for fast calibration and can be used to interface to a microcontroller. Figure 10 indicates the LED output signal in FAST mode. Figure 10: LED pulse output in fast mode To convert pulses per kilowatt-hour to frequency (in Hz) or vice versa the following equations can be used: ������������������������������������ = ����/��������ℎ ( 1000 × 3600 ���� × ���� ) ⁄ ����/��������ℎ = ������������������������������������ × ( 1000 × 3600 ���� × ���� ) where P/kWh is the LED or MON/MOP pulse constant I is the current in amperes V is the voltage (normally VNOM) Direction Indicator Output (DIRO) The direction of energy flow may be ascertained by monitoring the DIRO pin. A low level on this pin indicates negative energy flow. Positive energy flow is indicated on pin DIRO as a logic high. The DIRO pin may be used to drive an LED. t 1 t 4 t 2 MON MOP t 3 t 1 t 2 Time Amplitude Current Voltage Instantaneous Power Pulse Stability disabled (SO to V SS) Pulse Stability enabled (SO to V DD) 67-70µs |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |