6 / 12 page ![]() 6/12 sames sames SA9603B http://www.sames.co.za Synchronised Reading of Registers The SA9603B integrated circuit updates the registers on a continual basis. The SA9603B register content in latched onto the SPI interface as soon as a read command has been detected or the next register is addressed during continual access. The registers can be accessed at any time however for maximum stability the time between readings must be in multiples of 8 mains cycles. The internal offset cancellation procedure requires 8 mains cycles to complete. The registers are not reset after access, so in order to determine the correct register value the previous value read must be subtracted from the current reading. This methodology holds true for Active, Reactive and Voltage registers. The data read from the registers represents the active power, reactive power and voltage integrated over time. The increase of decrease between readings is the energy consumption. The registers are not affected during access. No error is possible during read, because all control signals are generated on chip. The registers can be accessed in any sequence at any time without problems. Dr-01498 Voltage +5V 0V (Vss) FM0 Figure 5: Fm0 Output The voltage sense zero crossing (approx. 50% duty cycle pulse) is available on Fm0, (Pin 15). This information allows a supervisor (ie: micro-controller) to monitor when the next read operation should be performed. Another approach could be to monitor the upper bits of the frequency register (18, 19). A measurement cycle is completed when these bits change to the same state again (00..00 or 01..01 or 10..10 or 11..11). Register Values The 24 bit registers are up/down counters, which increment or decrement at a rate of 640k*2/PI for reactive) at rated conditions. The energy register values will increment for positive energy flow and decrement for negative energy flow as can be seen in the following diagram: At power-up the register values are underfined and for this reason the msb of the delta value (delta value = present register value - previous register value) should be regarded as an indication of the measured energy direction. (0 = positive, 1 = negative). H7FFFFF (8388607) HFFFFFF (16777215) H800000 (8388608) 0 ............... ............... positive energy flow negative energy flow Register values register wrap around register wrap around |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |