| Electronic Components Datasheet Search |
|
TLE5012B Datasheet(PDF) 34 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE5012B Datasheet(HTML) 34 Page - Infineon Technologies AG |
|
34 / 50 page ![]() TLE5012B Specification Data Sheet 34 Rev. 2.0, 2014-02 Cyclic Redundancy Check (CRC) • This CRC is according to the J1850 Bus Specification. • Every new transfer restarts the CRC generation. • Every Byte of a transfer will be taken into account to generate the CRC (also the sent command(s)). • Generator polynomial: X8+X4+X3+X2+1, but for the CRC generation the fast-CRC generation circuit is used (see Figure 4-12) • The seed value of the fast CRC circuit is ’11111111B’. • The remainder is inverted before transmission. Figure 4-12 Fast CRC polynomial division circuit 4.4.2 Pulse Width Modulation (PWM) Interface The Pulse Width Modulation (PWM) interface can be selected via SSC (IF_MD = ‘01’). The PWM update rate can be programmed within the register 0EH (IFAB_RES) in the following steps: • ~0.25 kHz with 12-bit resolution • ~0.5 kHz with 12-bit resolution • ~1.0 kHz with 12-bit resolution • ~2.0 kHz with 12-bit resolution PWM uses a square wave with constant frequency whose duty cycle is modulated according to the last measured angle value (AVAL register). Figure 4-13 shows the principal behavior of a PWM with various duty cycles and the definition of timing values. The duty cycle of a PWM is defined by the following general formulas: (4.2) The duty cycle range between 0 - 6.25% and 93.75 - 100% is used only for diagnostic purposes. In case the sensor detects an error, the corresponding error bit in the Status register is set and the PWM duty cycle goes to the lower (0 - 6.25%) or upper (93.75 - 100%) diagnostic range, depending on the kind of error (see “Output duty cycle range” in Table 4-18). Except for an S_ADCT error, an error is only indicated by the corresponding diagnostic duty-cycle as long as it persists, but at least once. However the value in the status register will remain until a read- out via the SSC interface or a chip reset is performed. An S_ADCT error on the other side will be transmitted until the next chip reset. This fail-safe diagnostic function can be disabled via the MOD_4 register. Sensors with preset PWM are available as TLE5012B E50x0. xor X7 X6 X5 X4 X3 X2 xor X0 xor xor Input Serial CRC output & TX_CRC 1111 1 1 1 1 X1 parallel Remainder PWM PWM off on PWM PWM on t f t t t t t Cycle Duty 1 = + = = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |