| Electronic Components Datasheet Search |
|
TLE5012B Datasheet(PDF) 37 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE5012B Datasheet(HTML) 37 Page - Infineon Technologies AG |
|
37 / 50 page ![]() TLE5012B Specification Data Sheet 37 Rev. 2.0, 2014-02 In parallel to SPC, the SSC interface can be used for individual configuration. The number of transmitted SPC nibbles can be changed to customize the amount of information sent by the sensor. The frame contains a 16-bit angle value and an 8-bit temperature value in the full configuration (Table 4-19). Sensors with preset SPC are available as TLE5012B E9000 The status nibble, which is sent with each SPC data frame, provides an error indication similar to the Safety Word of the SSC protocol. In case the sensor detects an error, the corresponding error bit in the Status register is set and either the bit SYS_ERR or the bit ELEC_ERR of the status nibble will be “high”, depending on the kind of error (see Table 4-20). Except for an S_ADCT error, an error is only indicated by the corresponding error bit in the status nibble as long as it persists, but at least once. However the value in the status register will remain until a read-out via the SSC interface or a chip reset is performed. An S_ADCT error on the other side will be transmitted until the next chip reset. The fail-safe diagnostic function can be disabled via the MOD_4 register. 4.4.3.1 Unit Time Setup The basic SPC protocol unit time granularity is defined as 3 μs. Every timing is a multiple of this basic time unit.To achieve more flexibility, trimming of the unit time can be done within IFAB_HYST. This enables a setup of different unit times. Table 4-19 Frame configuration Frame type IFAB_RES Data nibbles 12-bit angle 00 3 nibbles 16-bit angle 01 4 nibbles 12-bit angle, 8-bit temperature 10 5 nibbles 16-bit angle, 8-bit temperature 11 6 nibbles Table 4-20 Structure of status nibble Name Bits Description SYS_ERR [3] Indication of system error (S_FUSE, S_OV, S_XYOL, S_MAGOL, S_ADCT) 0: No system error 1: System error occurred ELEC_ERR [2] Indication of electrical error (S_RST, S_VR) 0: No electrical error 1: Electrical error occurred S_NR [1] Slave number bit 1 (level on IFC) [0] Slave number bit 0 (level on SCK) Table 4-21 Predivider setting Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Unit time t Unit 3.0 μs IFAB_HYST = 001) 1) Not subject to production test - verified by design/characterization 2.5 IFAB_HYST = 011) 2.0 IFAB_HYST = 101) 1.5 IFAB_HYST = 111) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |