| Electronic Components Datasheet Search |
|
MP4054A Datasheet(PDF) 11 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP4054A Datasheet(HTML) 11 Page - Monolithic Power Systems |
|
11 / 19 page ![]() MP4054A – PRIMARY-SIDE CONTROL, OFFLINE LED CONTROLLER WITH ACTIVE PFC MP4054A Rev. 1.01 www.MonolithicPower.com 11 9/27/2017 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2017 MPS. All Rights Reserved. V REF—The feedback reference voltage (typical 0.413V); R S—The sensing resistor connected between the MOSFET source and GND. Power-Factor Correction (PFC) MULT is connected to a pull-up resistor from the rectified-instantaneous-line voltage; the multiplier output is sinusoidal. This signal sets the sinusoidal primary side peak current. This achieves a high power factor (PF). Inductor current Multiplier output Figure 4: Power-Factor Correction The maximum output voltage of the multiplier is clamped to 2.0V, setting the cycle-by-cycle current limit. VCC Under-Voltage Lockout (UVLO) When the VCC voltage drops below the UVLO threshold 9.5V, the IC stops switching and shuts down; the operating current is very low under this condition. VCC is then charged by the external resistor from the AC line. Figure 5 shows the typical waveform of UVLO. VCC Switching Pulses And Regulates the VCC Auxiliary Winding Takes Charge Protection happens 9.5 V 25.5 V Internal Gate 0 Figure 5: VCC Under-Voltage Lockout Auto Starter The MP4054A integrates an auto-restart that begins timing when the MOSFET turns off. If ZCD fails to send a turn-on signal after 190µs, a turn-on signal is initiated. This avoids an unnecessary IC shut down if ZCD misses detection. Minimum Off Time The MP4054A operates with variable switching frequency. The frequency changes with the input instantaneous line voltage. To limit the maximum frequency and enhance EMI performance, the chip employs an internal minimum OFF-time of 5.5µs. Leading-Edge Blanking (LEB) Internal leading-edge-blanking (LEB) is employed to prevent a switching pulse from terminating prematurely due to parasitic capacitance discharging when the MOSFET turns on. During the blanking time, the path from CS/ZCD to the current comparator input is blocked. Figure 6 shows the leading-edge blanking time. The LEB time of primary-side OCP detection is relatively short at 280ns. Figure 6: Leading-Edge Blanking Output Over-Voltage Protection (OVP) Output over-voltage protection prevents component damage from over-voltage conditions. The auxiliary winding’s positive plateau voltage is proportional to the output voltage; the OVP uses the auxiliary-winding voltage instead of directly monitoring the output voltage. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |