| Electronic Components Datasheet Search |
|
MP4054A Datasheet(PDF) 12 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP4054A Datasheet(HTML) 12 Page - Monolithic Power Systems |
|
12 / 19 page ![]() MP4054A – PRIMARY-SIDE CONTROL, OFFLINE LED CONTROLLER WITH ACTIVE PFC MP4054A Rev. 1.01 www.MonolithicPower.com 12 9/27/2017 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2017 MPS. All Rights Reserved. Figure 7 shows the OVP circuit. Once the ZCD voltage is higher than 5.1V and exceeds the OVP blanking time (during the gate turn-off interval), the OVP signal is latched, turning the gate driver off. When VCC drops below UVLO, the IC restarts. The output OVP setting point is calculated as: AUX ZCD2 OUT _ OVP SEC ZCD1 ZCD2 NR V 5.1V N R R V OUT_OVP—The output over-voltage protection point; N AUX— The auxiliary winding turns; N SEC— The secondary winding turns R1 RZCD2 RZCD1 Gate CS/ZCD 5.1V + - Latch OVP Blanking time Gate_OFF Figure 7: OVP Sampling Unit To prevent a voltage spike from an OVP mis- trigger, OVP sampling has a tLEB_OVP blanking period, typically 1.6µs when VMULT_O > 0.3V and 0.8µs when VMULT_O ≤ 0.3V (see Figure 8). V CS/ZCD 0 V Sampling Here t LE B _OV P Figure 8: ZCD Voltage and OVP Sampler A current-limit resistor between the output of the auxiliary winding and the ZCD resistor divider also works as a suppresser to avoid an OVP mis-trigger. Output Short-Circuit Protection (SCP) If an output short occurs, ZCD cannot detect the transformer’s zero-current-crossing signal, so the 19 0μs auto-restart timer triggers the MOSFET’s turn-on signal. The switching frequency of the power circuit drops to about 5kHz and the output current is limited to its nominal current. The auxiliary-winding voltage drops to follow the secondary-winding voltage, VCC drops to less than the UVLO threshold, and then the system restarts. This sequence limits both the output power and IC temperature if an output short occurs. Primary-Side Over-Current Protection (OCP) The primary-side over-current protection prevents device damage from excessive current, such as a primary winding short circuit. If the CS/ZCD voltage rises to 2.46V during the gate turn-on interval (see Figure 9), the primary-side over-current protection signal is latched, turning the gate driver off. When VCC drops below UVLO, the IC restarts. Figure 9: Primary-Side OCP Sampling Unit Brown-Out Protection The MP4054A has brown-out protection; the internal peak detector detects the peak value of the rectified sinusoid waveform on MULT. If the peak value is less than the brown-out protection threshold, 0.3V for typically 42ms, MP4054A identifies this as a brown-out, dropping COMP to zero and disabling the power circuit. If the peak value exceeds 0.4V, the IC restarts and the COMP voltage rises again softly. This feature prevents the transformer and LED current from saturating during fast ON/OFF switching (see Figure 10). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |