| Electronic Components Datasheet Search |
|
FUSB307B Datasheet(PDF) 39 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
FUSB307B Datasheet(HTML) 39 Page - ON Semiconductor |
|
39 / 57 page ![]() www.onsemi.com 39 Table 40. FAULTCTRL Address: 1Bh Reset Value: 0x00 Type: Read/Write Bit # Name R/W/C Size (Bits) Fault Control Description 7:4 Reserved R 4 Reserved: 0000b 3 DISCH_TIMER_DIS R/W 1 Auto and Force VBUS Discharge Timer Enable 0b: VBUS Discharge timer is enabled 1b: VBUS Discharge timer is disabled 2 Reserved R 1 Reserved: 0b 1 Reserved R 1 Reserved: 0b 0 VCONN_OCP_DIS R/W 1 VCONN OCP Enable 0b: VCONN OCP Enabled 1b: VCONN OCP Disabled Table 41. PWRCTRL Address: 1Ch Reset Value: 0x60 Type: Read/Write Bit # Name R/W/C Size (Bits) Power Control Description 7 Reserved R 1 Reserved: 0b 6 DIS_VBUS_MON (Note 25) R/W 1 Controls VBUS_VOLTAGE_L Monitoring. 0b: VBUS Voltage Monitoring is enabled 1b: VBUS Voltage Monitoring is disabled 5 DIS_VALARM R/W 1 Disables VALARMHCFGL and VALARMLCFGL 0b: Voltage Alarm reporting is enabled 1b:Voltage Alarm reporting is disabled 4 AUTO_DISCH (Notes 26, 28) R/W 1 Auto Discharge on Disconnect 0b: Turn Off Automatically Discharge VBUS based on VBUS Voltage 1b: Turn On Automatically Discharge VBUS based on VBUS Voltage 3 EN_BLEED_DISCH (Note 30) R/W 1 Enable Bleed Discharge 0b: Disable bleed discharge of VBUS 1b: Enable bleed discharge of VBUS 2 FORCE_DISCH (Note 27, 29) R/W 1 Force Discharge 0b: Disable forced discharge of VBUS 1b: Enable forced discharge of VBUS 1 VCONN_PWR R/W 1 VCONN Power Supported Writing this bit has no function. Please use VCONN_OCP to set OCP values 0 EN_VCONN R/W 1 Enable VCONN 0b: Disable VCONN Source (default) 1b: Enable VCONN Source to CC 25. If VBUS_MON is disabled, VBUS_VOLTAGE_L and VBUS_VOLTAGE_H reports all zeroes. 26. Setting this bit in a Source FUSB307B triggers the following actions upon disconnection detection: 1. Disable sourcing power over Vbus 2. VBUS discharge 27. Sourcing power over Vbus shall be disabled before or at same time as starting VBUS discharge. 28. Setting this bit in a Sink FUSB307B triggers the following action upon disconnection detection: 1. VBUS discharge 29. The FUSB307B will automatically disable discharge once the voltage on VBUS is below vSafe0V (max.). 30. Bleed Discharge is a low current discharge to provide a minimum load current if needed. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |