10 / 31 page ![]() Functional Description (Continued) White Data The White Data function generates all “1” data beginning at line 769 and continuing until the beginning of the next frame. This function is controlled via D6 Register Bit 7. Timing Control The Timing Control function generates control to column drivers, row drivers, and power supply. The programmable GPOs provide for CD latch pulse, REV, and gate driver control generation. The GPOs allow the user to generate control anywhere within the frame data. Standard gate driver interface or custom gate interfaces can be implemented with the nine GPOs. Note that GPO [8] must be used for output blanking control. Five registers provide the timing definition for each GPO. The Horizontal Start register defines the output pixel number for which the GPO output goes active. The Horizontal dura- tion register determines how many clocks the output will remain active during the line. The Vertical Start register defines at what line # the output becomes active, and the Vertical duration register defines how many lines the output remains active. Each output has a control register (bit 0) which defines the GPO polarity (active high or low). Another bit in the control register (bit 1) enables the “toggle” mode. This mode is useful in REV generation when alternating polarity is required from line to line. Frame to Frame polarity changes are made by programming an odd # in the vertical duration register when in “toggle” mode. Please note that ODD Frame size inputs are not supported in ’’toggle mode’’ function. Two of the General Purpose Outputs have additional capa- bilities. GPO [8] controls output blanking and must be used for this purpose. If output blanking is not desired, this register must be programmed to always be active. White data gen- eration (all “1” data) at the end of each frame is generated when D6 register bit 7 is set. When this bit is set, white data is output after line #768 if GPO [8] is active. GPO [0] is capable of performing line inversion on the output data. Bits [5:3] of the Output Format Control register provides control for this function. See APPENDIX A: GPO Programming Examples. SERIAL EEPROM INTERFACE The Serial EEPROM Interface controls the FPD85308 initial- ization. If the EEPROM is not present (EESD and EESC are pulled high), or if EEPROM address 80H is not “00”, the internal default values are used to initialize all programmable functions of the FPD85308. At power-up, the FPD85308 configures the internal program- mable registers with data from the EEPROM. After the FPD85308 is initialized, the EEPROM can be accessed by the system in which display configuration and manufacturing information can be obtained. The EEPROM can be pro- grammed “in system” providing quick evaluation of different display timing. External access to the EEPROM must be preceded by ap- plying a “1” to pin TEST [2] in order to interrupt the FPD85308 download. The FPD85308 initialization data begins at EEPROM ad- dress 80H. The first 128 bytes (0-7F) are reserved for dis- play identification data. A power-up delay can be programmed using bits [6:5] of the Input Format Control Register. This delays outputting (driv- ing) of the data and control for up to 5 frame times after reset. The TEST [2] pin must be low for a power-up delay to occur. VERTICAL/HORIZONTAL REFERENCE GENERATOR This block provides Vertical and Horizontal Reference points for the Timing Control Function. VSYNC, HSYNC and ENAB along with programmable control from the input control reg- ister bits 0 and 1 (FIX HORIZONTAL and FIX VERTICAL) are used to determine when the video from the host is valid. Three input modes are supported. See Table 1. Fixed Vertical, Fixed Horizontal The horizontal timing is fixed and determined by the Hori- zontal Backporch register. The vertical timing is also fixed and determined by the Vertical Backporch register. ENAB is ignored and is not necessary. Fixed Vertical, ENAB Controlled Horizontal The horizontal timing is controlled by the ENAB timing. The vertical timing is fixed and determined by the Vertical Back- porch register and HSYNC input. ENAB Only In ENAB Only timing, VSYNC and HSYNC are ignored. All timing is derived from the ENAB signal. www.national.com 10 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |