16 / 30 page ![]() AP72200 Application Information (continued) H-Bridge Controller (continued) The regulator enters PFM as the output load decrease when the valley of the inductor current is less than 0A. The zero cross detection will activate after 40µs delay before switching the mode from PWM to PFM. During PFM operation in buck mode, Switch Q3 is closed and Switch Q4 is open. Switches Q1 and Q2 operate in discontinuous mode during PFM operation until output voltage is approximately 1.2% upper threshold of the PFM hysteretic controller. Then all switches are open to allow VOUT to decay until it reaches nominal regulation before switching again. This operation will reduce switching losses at light load thus improving efficiency. Likewise, the AP72200 closes Switch Q1 and Switch Q4 to ramp up the current in the inductor during PFM operation in boost mode. When the inductor current reaches 1A, the device turned OFF Switch Q4, then turn ON Switch Q3. With Switch Q3 closed, output voltage increases as the inductor current ramps down. When the loading current gets higher, there will be multiple PFM pulses to charge up the output capacitor. These pulses continue until VOUT has achieved the 1.2% upper threshold of the PFM hysteretic controller. Switching action then stops until VOUT decays until it reached normal regulation before switching again. The regulator resumes normal PWM operation as the output load increases and VOUT drops 2% below the regulation point. Regulator MODE Control AP72200 has a MODE pin as well as I 2 C enable bit. Connect MODE pin low sets the regulator to operate in PFM. Tie the MODE to VIN set the device in PWM. The MODE pin condition is set during the POR operation of the regulator and can only be overridden by the I 2 C. In the address number 0x02, bit 6 and bit 0 are BB_UMODE and BB_FPWM respectively. These two bits can set the mode of operation of PFM, enhanced ultrasonic, or forced PWM. When the enhanced ultrasonic is set, this activates a unique pulse-skipping mode with a minimum switching frequency of 20kHz. An ultrasonic pulse occurs when the regulator detects that no switching has occurred after 37µs. Once triggered, the ultrasonic pulse turned on the switch Q2 (buck mode) or Q3 (boost mode) for approximately 50ns to induce a negative inductor current. This process continues until FB drops to the regulation point. Then the regulator waits for the next clock edge to initiate the ON time. Table 2 is the truth table for the MODE operation found in I 2 C address 0x02. BIT6 BIT0 Operating Mode 0 0 PFM 1 0 Ultrasonic Mode x 1 PWM Table 2 MODE Control Table Power-Good (PG) Indicator Buck-boost has an open-drain output that is actively held low during soft-start period until the output voltage reaches 80%. When the output voltage is outside of its regulation by -20%, the PG will pull low until the output returns to set value. The PG low-to-high transition is delayed by 1.5ms while the falling edge PG is delayed by 3µs to prevent false triggering. The polarity of PG output is programmable through I 2 C in address 0x03 bit 4. It is active high by default. Overcurrent Protection AP72200 has an OCP pin as well as an I 2 C enable bit to adjust the threshold 2A or 4.3A. The OCP pin control setting is the condition upon POR operation of the regulator and can only be overridden by the I 2 C. The AP72200 detects the current limit on the high side, Q1, to protect the device against overload or short-circuit conditions. The peak current in the switch is monitored cycle by cycle with comparator delay approximately 100ns to guard against noise glitches. If the high-side Q1 current limit is reached, the high-side Q1 is turned off, and the low-side Q2 is turned on until the switch current decreases below OC threshold. The frequency is reduced in order to protect the device from damage. The Q1 peak current limit remains active during this state. After 17 consecutive cycles in OCP event, the regulator enters hiccup mode where all power FETs turn off and wait for 15ms before attempting to restart. Reverse Current Protection During fixed-frequency operation, a reverse-current comparator on switch Q2 monitors the current entering VOUT. When this current exceeds 2A (typical), switch Q2 will be turned off for the remainder of the switching cycle. This feature protects the buck-boost converter from excessive reverse current if the buck-boost output is held above the regulation voltage by an external source. Undervoltage Lockout The undervoltage lockout (UVLO) feature prevents abnormal operation in the event that the supply voltage is too low to guarantee proper operation. When the VIN voltage falls below the UVLO threshold, the regulator is disabled. AP72200 Document number: DS40869 Rev. 3 - 2 16 of 30 www.diodes.com July 2018 © Diodes Incorporated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |