| Electronic Components Datasheet Search |
|
AP72200 Datasheet(PDF) 18 Page - Diodes Incorporated |
|
|
|||||||||||||||||||||||||||||
AP72200 Datasheet(HTML) 18 Page - Diodes Incorporated |
|
18 / 30 page ![]() AP72200 Serial Interface The I 2C compatible 2-wire serial interface is used for regulator on/off control, setting output voltages, and other functions. See the Register Map section for details. The I 2C interface is an open-drain serial bus that consists of a bidirectional serial data line (SDA) and a serial clock line (SCL). Pull- up resistors of 500Ω each or greater must be added from VIO to SDA and VIO to SCL. Optional 24Ω resistors in series with SDA and SCL help protect the device inputs from high voltage spikes on the bus lines. Series resistors also minimize crosstalk and undershoot on bus lines. System Configuration Figure 3 Functional Logic Diagram for Communications Controller The I 2C bus is a multi-master bus. The maximum number of devices that can attach to the bus is limited by bus capacitance. Figure 3 shows an example of a typical I 2C system. A transmitter is a device on the I2C bus that sends data to the bus. A receiver is a device that receives data from the bus. The master is a device that initiates a data transfer and generates the SCL clock signal to control the data transfer. A slave is any device on the bus that can be addressed by the master. When the AP72200 I 2C compatible interface is operating, it is a slave on I2C bus. Bit Transfer One data bit is transferred for each SCL clock cycle. The data on SDA must remain stable during the high portion of SCL clock pulse. Changes in SDA while SCL is high are control signals (START and STOP conditions). Figure 4 I 2 C Bit Transfer START and STOP Conditions When the I 2C serial interface is inactive, SDA and SCL are pulled high. A master device initiates communication by issuing a START (S) condition. A START condition is a high-to-low transition on SDA while SCL is high. A STOP (P) condition is a low-to-high transition on SDA while SCL is high. A START condition from the master signals the AP72200 that a transmission is about to begin. The master terminates transmission and frees the bus by issuing a STOP condition. To issue a series of commands to the slave, the master may issue REPEATED START (Sr) conditions instead of a STOP condition in order to maintain control of the bus. In general, a REPEATED START condition is functionally equivalent to a regular START condition. AP72200 will listen for its address after a START condition is detected. If its address is not detected, it will stay idle until the next START condition is detected. Figure 5 Start and Stop Conditions AP72200 Document number: DS40869 Rev. 3 - 2 18 of 30 www.diodes.com July 2018 © Diodes Incorporated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |