23
SOLOMON
SSD1815B
Rev1.6
07/2002
Set Bias Ratio
Except the 1/4 bias, all other available bias ratios could be
selected using this command plus the “Set LCD Bias” command.
For detail setting values and POR default, please refer to
the extended command table, Table 5 on page 18.
Set Temperature Coefficient (TC) Value
4 different temperature coefficient settings is selected by
this command in order to match various liquid crystal tempera-
ture grades. Please refer to the extended command table, Table
5 on page 18, for detail TC values.
Modify Oscillator Frequency
The oscillator frequency can be fine tuned by applying this
command. Since the oscillator frequency will be affected by
some other factors, this command is not recommended for gen-
eral usage. Please contact SOLOMON Systech Limited applica-
tion engineers for more detail explanation on this command.
Set 1/4 Bias Ratio
This command sets the bias ratio directly to 1/4. This bias
ratio is especially designed for use in under 12 mux display.
In order to restore to other bias ratio, this command must be
executed, with LSB=0, before the “Set Multiplex ratio” or “Set
LCD Bias” command is sent.
Set Total Frame Phases
The total number of phases for one display frame is set by
this command.
The Static Icon is generated by the overlapping of the M and
MSTAT signals. These two pins output either VSS or VDD at
same frequency but with phase different.
To turn on the Static Icon, 3 phases overlapping is applied
to these signals, while 1 phase overlapping is given to the Off
status.
The more the total number of phases in one frame, the less
the overlapping time and thus the lower the effective driving volt-
age at the Static Icon on the LCD panel.
Set Display Offset
This command should be sent ONLY when the multiplex ra-
tio is set less than SSD1815B’s default value.
When a lesser multiplex ratio is set, the display will be
mapped in the middle (y-direction) of the LCD, see the no offset
columns on Table 8 on page 21. Use this command could move
the display vertically within the 64 commons.
To make the Reduced-Mux Com 0 (Com 0 after reducing
the multiplex ratio) towards the Row 0 direction for L lines, the 6-
bit data in second command should be given by L. An example
for 7 line moving towards to Com0 direction is given on Table 8
on page 21.
To move in the other direction by L lines, the 6-bit data
should be given by 64-L.
Please note that the display confined within SSD1815B’s
default multiplex value. That is the maximum value of L is given
by the half of the default value minus the reduced-multiplex ratio.
For an odd display mux after reduction, moving away from Row
0 direction will has 1 more step.