4 / 10 page ![]() 2011/11/14 Rev.A.8 4 EM5103 Dropout Voltage (Note 7) VDROP IOUT=2A, VCNTL=VEN=5V, VOUT= VREF - 200 240 mV IOUT=3A, VCNTL=VEN=5V, VOUT=VREF - 300 360 mV Output Voltage VOUT 0.8 - VCNTL-2 V VOUT Pull Low Resistance VIN=VCNTL=5V, VEN=0V - 70 - Ω Enable Enable High Level VEN 1.4 - - V Disable Low Level VSD - - 0.4 V Enable Source Current IEN VCNTL=5V, VEN=0V - 7 18 μA Enable Input Impedance ZEN - 700 - KΩ Output Voltage Ramp Up Time 1.5 2.5 4.5 ms PWROK FB Power OK Threshold VPOKTH VIN=VCNTL=VEN=5V, IOUT=0A, VOUT=VREF - 90 - % Power OK Hysteresis VPOKHYS VIN=VCNTL=VEN=5V, IOUT=0A, VOUT=VREF - 8 - % POK Delay Time From VOUT>90% to POK rising 0.5 1.0 2.0 ms Over Current Protection OCP Threshold Level IOCP VIN=VCNTL=VEN=5V, VOUT=VREF 3.2 4.0 - A Output Short Circuit Current ISC VIN=VCNTL=VEN=5V, VOUT=0V 1.5 2.5 - A Thermal Protection Thermal Shutdown Temperature TSD VIN=VCNTL=VEN=5V, IOUT=0A, VOUT=VREF - 160 - °C Thermal Shutdown Hysteresis TSDHYS VIN=VCNTL=VEN=5V, IOUT=0A, VOUT=VREF - 30 - °C Note 1. Stresses listed as the above “Absolute Maximum Ratings” may cause permanent damage to the device. These are for stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may remain possibility to affect device reliability. Note 2. θ JA is measured in the natural convection at TA=25 oC on a 4-layers high effective thermal conductivity test board with minimum copper area of JEDEC 51-7 thermal measurement standard. The case point of θ JC is on the expose pad for PSOP-8 package. Note 3. θJA PSOP-8 packages is 52°C /W on JEDEC 51-7 (4 layers,2S2P) thermal test board with 50mm 2 copper area. Note 4. Devices are ESD sensitive. Handling precaution is recommended. Note 5. The device is not guaranteed to function outside its operating conditions. Note 6. Load regulation is measured by a current pulse with 50Hz frequency and 10% duty cycle. Note 7. The dropout voltage is defined as (VIN-VOUT), which is measured when VOUT equal to (VOUT,(NORMAL)-100mV). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |