| Electronic Components Datasheet Search |
|
TIMS Datasheet(PDF) 2 Page - TOKYO SEIMITSU CO., LTD |
|
|
|||||||||||||||||||||||||||||
TIMS Datasheet(HTML) 2 Page - TOKYO SEIMITSU CO., LTD |
|
2 / 2 page ![]() Each program can be easily linked to an icon Appropriate windows are provided for each piece of hard- ware, and hardware can be selected simply by clicking the applicable icon. The system is designed and engineered to maximize performance and efficiency. High efficiency measur- ing A collection of powerful tools support high efficiency measuring, including teaching/playback for full automatic measuring, multitasking for parallel processing and high- speed alignment, and much more. The screen layout can be customized to create a streamlined working environment that balances function and ease of operation for a variety of different workpiece conditions and operator skills. The screen has optimized for the wider screens that will be used in the future. For contour measuring in particular, functions that support measur- ing itself are arranged to facilitate easy operation. Workpiece Trace A pre-measuring coordinate trace can be performed to check the measur- ing surface in cases when there is a partition between the start point and the end point, when ascertaining the measuring limit points while measur- ing right up to a depression, or when visual inspection is difficult (as with the inside of a hole). To eliminate measuring error, the measuring range can be defined on-screen by specifying the start point and end point. Measuring screen Analysis screen Automatic Dimension Line Output Function Pre-selecting the dimension lines of the required elements will display the dimen- sion lines along with the calculation. After calculation, dimension lines can be added, moved or deleted as required. Cursor Profile Discrimination The operator can superimpose a freely created cursor range on contour data for calculation. This means that a calculation which used to require two clicks can now be done with a single drag operation. Allowable Element Calculation Icon Guidance This function provides a visual display of elements that can be calculated when performing a new calculation using any one of multiple elements for which calculations have already been completed. Even when selecting between complex elements, this function enables intuitive selection in accordance with the objective of the calculation. Calculation Result Preview When auto calculation is turned off, calculation results and dimension lines appear in the preview screen as soon as the cursor is superimposed, so that calculation results can be previewed before they are finalized. When calculation range expansion is enabled, preview can be used to check the condition of the calculation range expansion, which helps to prevent calculation and opera- tion errors. Specifications TiMS Contour Measurement and Analysis Program AI function Automatic distinction of elements including points, straight lines and circles Automatic distinction of the combination executable of calculation between two elements (point-point, point-straight line, point-circle, point-oval, straight line-straight line, circle-straight line, circle-circle, straight line-oval, circle-oval, oval-oval) Arithmetic processing Point, line, circle, partial circle, ellipse, max. point/min. point, distance, coordinate difference, polar coordinate difference, orthogonal/polarcoordinate difference display, intersecting elements (point-line, line-line, circle-line, circle-circle, line-ellipse), symmetric elements (point-point, point-circle, point-ellipse, line-line, circle-circle, circle-ellipse, ellipse-ellipse), surface calculation, over-pin calculation, dimension line display function, calculation result/nominal value collation, mirror reversal, profile synthesis function, macro function, automatic element discrimination, calculation point repeat function, workpiece trace function, peak and valley function, auto operation log/playback function [profile nominal value collation, best fit, design value generation, IGES/DXF conversion] Coordinate control Origin setting, X-axis setting, parallel move, and rotary move Measure pitch 0.1 μm to 1000 μm Number of data points Maximum 150000 points Magnification display 0.01 to 10000000 times (arbitrary and automatic) TiMS Integrated Measuring System Software Contour Profile Measurement and Analysis Program 67 TOKYO SEIMITSU |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |