Electronic Components Datasheet Search
  English  ▼

X  

AMT49700 Datasheet(PDF) 39 Page - Allegro MicroSystems

Part # AMT49700
Description  Automotive Stepper Driver
PDF  45 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ALLEGRO [Allegro MicroSystems]
Direct Link  http://www.allegromicro.com
Logo ALLEGRO - Allegro MicroSystems

AMT49700 Datasheet(HTML) 39 Page - Allegro MicroSystems

Back Button AMT49700 Datasheet HTML 35Page - Allegro MicroSystems AMT49700 Datasheet HTML 36Page - Allegro MicroSystems AMT49700 Datasheet HTML 37Page - Allegro MicroSystems AMT49700 Datasheet HTML 38Page - Allegro MicroSystems AMT49700 Datasheet HTML 39Page - Allegro MicroSystems AMT49700 Datasheet HTML 40Page - Allegro MicroSystems AMT49700 Datasheet HTML 41Page - Allegro MicroSystems AMT49700 Datasheet HTML 42Page - Allegro MicroSystems AMT49700 Datasheet HTML 43Page - Allegro MicroSystems Next Button
Zoom Inzoom in Zoom Outzoom out
 39 / 45 page
background image
Automotive Stepper Driver
AMT49700
39
Allegro MicroSystems, LLC
955 Perimeter Road
Manchester, NH 03103-3353 U.S.A.
www.allegromicro.com
Motion Control with the Step Sequencer
The basic operation of the programmable step sequencer is
described in the “Stepper Motor Motion Control” section. The
motion is described by 5 programmable variables, giving the
start step rate, run step rate, acceleration, deceleration, and the
total number of steps to take. These are illustrated in Figure 5,
repeated here.
In the normal single sequence from a stationary state shown in
Figure 5, the sequencer will begin by stepping the motor at the
programmed start rate for the first step. The following steps will
increase in step rate according to the programmed acceleration
until the motor reaches the run step rate. At each step, the total
step count remaining is reduced by one. The motor continues to be
stepped at the run step rate until the step count reaches the number
of steps required to decelerate the motor, based on the present step
rate, the start rate, and the deceleration factor. At this point, the step
rate is reduced at each step according to the programmed decelera-
tion until the motor reaches the start step rate at the step count.
Once the step count is reached the motor is stopped.
If the number of steps is insufficient to accelerate to the full run
speed, the sequencer will accelerate the motor until it reaches the
number of steps required to decelerate the motor for the present
speed and will then change immediately to deceleration as shown
in Figure 19. The motor will then continue to decelerate until the
motor reaches the step count.
A single sequence is relatively simple to comprehend, but it is
also possible to change the variables when a step sequence in in
progress. A sequence can only start or be changed on the rising
edge of the STRn input following the writing of the least signifi-
cant 8 bits of the step count variable, NSL (the serial interface
timing sequence is shown in Figure 2). Any changes to the start
or run speed settings, the acceleration, deceleration, or the most
significant 8 bits of the step count variable will have no effect
until the least significant 8 bits of the step count variable are suc-
cesfully written.
If a change occurs when the sequence is in progress, the step
sequencer will either continue running at the run step rate,
accelerate the motor or decelerate the motor (Figure 20). The
step count will be updated with the new step count. If there is
no change to the most significant 8 bits of the step count, then
the previous value will be retained and only the least significant
8 bits will be changed. If only the step rate is changed, then the
least significant 8 bits of the step count should be written with the
same value as the original programmed input.
There are many profile change combinations possible. The fol-
lowing examples provide the response to specific changes as
examples from which it should be possible to extrapolate other
possible responses.
Figure 5: Step Profile Parameters
Step Rate
Run
Rate
Start
Rate
Step Count
Steps
Acceleration
Deceleration
Figure 19: Low Step Count
Step Rate
Run
Rate
Start
Rate
Step Count
Steps
Figure 20: Run Speed Change
Start
Rate
Steps
Inital
Run
Rate
Increased
Run Rate
Reduced
Run Rate
Step Rate
Accelerates
to new level
Step Rate
Decelerates
to new level



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com