13 / 45 page ![]() Automotive Stepper Driver AMT49700 13 Allegro MicroSystems, LLC 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com Stepper Motor Motion Control The AMT49700 provides two methods of motion control, a single-step mode and a programmed step-sequence mode. Single- step mode can be controlled either by STEP and DIR terminals or through the serial interface. Step-sequence mode can only be controlled through the serial interface. SINGLE-STEP CONTROL The single-step mode is accessed by writing a step change value into the SC[5:0] variable. The step change value is a two’s complement (2’sC) number, where a positive value moves the motor forward by a number of 1/16th microsteps and a negative value moves the motor backwards by a number of 1/16th micro- steps. For example, for a full-step forwards the decimal number 16 would be written to SC. For a half step backwards the number -8 would be written to SC. Further details and examples are pro- vided in the applications section. The Step and Direction control mode uses the STEP and DIR terminals. When using Step and Direction mode to control stepper motor, the AMT49700 automatically increases or decreases the Step Angle Number according to the step sequence associated with the selected step mode. The default step mode, reset at power-up or after a power-on reset, is half step. Full-, quarter-, and sixteenth- step sequences are also available when using the STEP and DIR inputs and are selected by the contents of MS[2:0]. STEP-SEQUENCE CONTROL The step-sequence mode provides the ability to command the motor to run a number of steps in either direction following a programmable accelerate, run and decelerate profile. The acceleration, deceleration, running step rate, starting step rate, total number of steps and direction can all be configured inde- pendently through the serial interface by writing to the following variables: ACC[5:0]: Acceleration in Full steps/s2 DEC[5:0]: Deceleration in Full steps/s2 SSR[5:0] Starting Step rate in Full steps/s RSR[5:0] Running Step rate in Full steps/s DIR Direction NSM[7:0] Most significant 8 bits of the step count NSL[7:0] Least significant 8 bits of the step count All step profile parameters are based on full step units except the target steps, NSM[7:0] and NSL[7:0]. The actual motor speed, acceleration, deceleration and number of steps will always be the same regardless of the selected microstep resolution. The sequence will start or change when STRn goes high at the end of the transfer of NSL[7:0], the least significant 8 bits of the step count number. When a programmed step seqence is com- plete, the motor will remain stopped until the end of the next NSL[7:0] transfer. When a programmed step seqence is in prog- ress, the STEP and DIR inputs are ignored. The logic level on the DIR input has no effect on step-sequence control. In this operat- ing mode, the direction is only defined by the DIR bit. Opera- tional direction can be read on DIRR in Register 13 via serial interface either in the STEP and DIR mode or the Motion Control mode. The DIRR data is latched at the STRn signal taking low. Figure 5 shows the definition of the basic step profile parameters and the sequence that occurs when the least significant 8 bits of the step count number are written. From a stationary state, the AMT49700 will begin by stepping the motor at the programmed start rate for the first step. The following steps will increase in step rate according to the programmed acceleration until the motor reaches the run step rate. At each step, the total step count remaining is reduced by one. The motor continues to be stepped at the run step rate until the step count reaches the number of steps required to decelerate the motor based on the run rate, the start rate and the deceleration factor. At this point the step rate is reduced at each step according to the programmed deceleration until the motor reaches the start step rate. Once the start step rate is achieved, the motor is stopped. Step Rate Run Rate Start Rate Step Count Steps Acceleration Deceleration Figure 5: Step Profile Parameters It is possible to change the variables when the step sequence is in progress, but the changes only take effect when the lsb of the step count is written. The effect of any change will depend on the present state of the step sequence. In each case, the AMT49700 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |