7 / 23 page ![]() Programmable Microelectronics Corp. Issue Date: March, 2004, Rev: 1.3 PMC Pm39F010 / Pm39F020 / Pm39F040 7 BLOCK DIAGRAM DEVICE OPERATION READ OPERATION The access of Pm39F010/020/040 are similar to EPROM. To read data, three control functions must be satisfied: • CE# is the chip enable and should be pulled low ( VIL ). • OE# is the output enable and should be pulled low ( VIL). • WE# is the write enable and should remains high ( VIH ). PRODUCT IDENTIFICATION The product identification mode can be used to identify the manufacturer and the device through hardware or software read ID operation. See Table 1 for PMC Manu- facturer ID and Device ID. The hardware ID mode is acti- vated by applying a 12.0 Volt on A9 pin, typically used by an external programmer for selecting the right pro- gramming algorithm for the devices. Refer to Table 2 for Bus Operation Modes. The software ID mode is acti- vated by a three-bus-cycle command. See Table 3 for Software Command Definition. WE# CE# OE# COMMAND REGISTER CE,OE LOGIC A0-A MS ERASE/PROGRAM VOLTAGE GENERATOR HIGH VOLTAGE SWITCH I/O0-I/O7 I/O BUFFERS DATA LATCH SENSE AMP Y-GATING MEMORY ARRAY Y-DECODER X-DECODER BYTE PROGRAMMING The programming is a four-bus-cycle operation and the data is programmed into the devices (to a logical “0”) on a byte-by-byte basis. See Table 3 for Software Com- mand Definition. A program operation is activated by writ- ing the three-byte command sequence followed by pro- gram address and one byte of program data into the devices. The addresses are latched on the falling edge of WE# or CE# whichever occurs later, and the data are latched on the rising edge of WE# or CE# whichever occurs first. The internal control logic automatically handles the internal programming voltages and timing. A data “0” can not be programmed back to a “1”. Only erase operation can convert the “0”s to “1”s. The Data# Polling on I/O7 or Toggle Bit on I/O6 can be used to detect the progress or completion of a program cycle. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |