| Electronic Components Datasheet Search |
|
ZSC31010 Datasheet(PDF) 23 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSC31010 Datasheet(HTML) 23 Page - Renesas Technology Corp |
|
23 / 44 page ![]() ZSC31010 Datasheet © 2016 Integrated Device Technology, Inc. 23 January 20, 2016 ZACwire TM Output Calculation 160 ms Settling Time 64 ms Power-On Settling 128 ms Power Down (determined by Update Rate) ADC Conversion 768 ms Calculation 160 ms ZACwire TM Output Table 3.2 shows the idle time between packets versus the update rate. This idle time can vary by nominal +/-15% between parts, and over a temperature range of -50 to 150ºC. Transmissions from the IC occur at one of two speeds depending on the update rate programmed in EEPROM. If the user chooses one of the two fastest update rates (1 ms or 5 ms) then the baud rate of the digital transmission will be 32 kHz (minimum 25 kHz). If, however, the user chooses one of the two slower update rates (25 ms or 125 ms), then the baud rate of the digital transmission will be 8 kHz (maximum 9.4 kHz). The total transmission time for both digital output configurations is shown in Table 3.2. Table 3.2 Total Transmission Time for Different Update Rate Settings and Output Configuration Update Rate Baud Rate* Idle Time Transmission Time – Bridge Only Readings Transmission Time – Bridge & Temperature Readings 1 ms (1 kHz) 32 kHz 1.0 ms 20.5 bits 31.30 µs 1.64 ms 31.0 bits 31.30 µs 1.97 ms 5 ms (200 Hz) 32 kHz 4.85 ms 20.5 bits 31.30 µs 5.49 ms 31.0 bits 31.30 µs 5.82 ms 25 ms (40 Hz) 8 kHz 22.5 ms 20.5 bits 125.00 µs 25.06 ms 31.0 bits 125.00 µs 26.38 ms 125 ms (8 Hz) 8 kHz 118.0 ms 20.5 bits 125.00 µs 120.56 ms 31.0 bits 125.00 µs 121.88 ms * Typical values. Minimum baud rate for 1 ms or 5 ms: 26kHz; maximum baud rate for 25 ms or 125 ms: 9.4kHz. The temperature raw reading is performed less often than a bridge reading, because the temperature changes more slowly. Table 3.3 shows the timing for the special measurements (temperature and bridge measurement) in the different update rate modes. Table 3.3 Special Measurement versus Update Rate Update Rate Setting Special Measurement 00 Every 128 bridge measurements 01 Every 64 bridge measurements 10 Every 16 bridge measurements 11 Every 8 bridge measurements It is easy to program any standard microcontroller to communicate with the ZSC31010. IDT can provide sample code for a MicroChip® PIC microcontroller. For update rates less than 1 kHz, the output is followed by a power-down, as shown below. Figure 3.9 ZACwire™ Output Timing for Lower Update Rates |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |