ADVANCEDCONTROLTECHNOLOGIES,INC.
Indianapolis, Indiana 46278
RF224 Installation Instructions
P/D 112700
CHECKOUT AND OPERATING PROCEDURE
1. Restorethepower.
2. Set the address as follows :
Connect a PCC transmitter such as the AT004 or any X10 compatible desktop transmitter to the
same power line as the RF224 test setup. Select the desired letter code. Press and hold the
PROGRAMpushbuttonontheRF224forjustoverthreesecondsandrelease. TheSTATUSLED
should be ON solid. The RF224 is now in PROGRAM mode. Press the desired number code on
the transmitter two times with a half second pause between transmissions to allow six zero
crossings to occur. The RF224 STATUS LED should blink two times and come back ON solid,
indicating that it is still in program mode. NOTE: When a new address is programmed into the
device, all the ADDITIONAL PROGRAMMING FEATURES are reset to their default values.
ADDITIONALPROGRAMMINGFEATURES:
RUDE/POLITE PROGRAMMING. The RF224 receivers close and open their relay contacts with
standard X10 ON and OFF commands, respectively. They also may be programmed to respond to
other commands. By default, the device operates in polite mode (waits for other powerline
transmissions to cease before transmitting and will monitor the powerline for collisions), but may be
configured to operate in rude mode (ignores other powerline transmissions when transmitting). To
disablePolitemode,afterprogrammingthebaseaddress,sendtheaddresstwoadditionaltimeswith
a half second pause between transmissions to allow six zero crossings to occur. The Status LED
will blink four times to signal the operator that the device will now operate in Rude mode.
Also, the device may be programmed to respond to other commands which may close the relay
(AllLightsON), or open the relay (AllUnitsOFF, or AllLightsOFF). These commands are disabled by
defaultwhenthebaseaddressofthedeviceisprogrammed. Toenablethesecommands,presstheir
respective command button two additional times with a half second pause between transmissions
to allow six zero crossings to occur. The Status LED on the RF224 will flash to indicate that the
command has been accepted. The table below illustrates the flashing pattern of the Status LED.
Flashing Pattern
Interpretation
¼ second ON, 3 seconds OFF
NormalOperation
ContinuousRapidFlash
EEPROMError
TwoFlashes
Valid base address accepted
Four Flashes
Polite mode disabled
Six Flashes
All Lights ON command enabled
Eight Flashes
All Units OFF command enabled
TenFlashes
All Lights OFF command enabled
Upon receiving a valid Status Request command, the device will transmit the current relay status,
eitherON(closed)orOFF(open). Notethatthereisnofeedbackfromtherelay. Iftherelayisswitched
manually, this will not be reflected in the software, nor in the Status Reply to the controller.
To exit the PROGRAM modepressthePROGRAMswitchontheRF224briefly.TheSTATUSLED
will go off. The RF224 will now respond to the programmed letter and number code and any other
programmed features. NOTE: It will also automatically exit PROGRAM one (1) minute after the last
AT004 or X10 compatible desktop transmitter transmission.
3. Operation(NormalMode)
a. To close the contact of the relay:
i. Send an ON command set to the base address of the unit.
ii. If the All Lights ON command is enabled, send an All Lights ON command.
b. To open the contact of the relay:
i. Send an OFF command set to the base address of the unit.
ii. If the All Units OFF command is enabled, send an All Units OFF command.
iii. If the All Lights OFF command is enabled, send an All Lights OFF command.



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com