| Electronic Components Datasheet Search |
|
BA8BM Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
BA8BM Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 6 page ![]() MODEL: BA8BM-DAC8 BA8BM-DAC8 SPECIFICATIONS ES-7341 Rev.3 Page 2/6 https://www.m-system.co.jp/ INPUT SPECIFICATIONS Number of input: 4 Isolation: Optical isolator Input resistance: Approx. 4.4 kΩ Common: 1 common per 4 points (4 terminals) Contact detecting: 24 V DC ±10% ON voltage/ON current: ≤ 12 V, ≥ 2.5 mA OFF voltage/OFF current: ≥ 17 V, ≤ 1.5 mA ON delay time: ≤ 2.0 msec. OFF delay time: ≤ 2.0 msec. ON detecting time: Approx. 5.0 msec. ■ PULSE INPUT SPECIFICATION Maximum frequency: 100 Hz (ON/OFF time ≥ 5 msec.) Totalized pulse range: 0 - 4,294,967,295 Max. totalized pulse range: 1,000 - 4,294,967,295 (Factory setting: 9,999,999) Count at overflow: Reset and restart at ‘0'. OUTPUT SPECIFICATIONS Number of output: 4 points Common: 1 common per 1 point Rated load: 250 V AC @ 2A, 30 V DC @ 2A Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 500 VA (AC), 60 W (DC) Minimum applicable load: 24 V DC @ 5 mA Relay life Mechanical: 2 × 107 cycles (180 cycles per min.) When driving an inductive load, external contact protection and noise quenching recommended. ON delay time: ≤ 10 msec. OFF delay time: ≤ 10 msec. Output data update time: Approx. 300 msec. INSTALLATION Power consumption •AC: Approx. 5 VA at 100 V Approx. 7 VA at 200 V Approx. 8 VA at 240 V Operating temperature: 0 to 50°C (32 to 122°F) Operating humidity: 10 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: DIN rail Weight: 350 g (0.77 lb) PERFORMANCE Battery backup: RTC (for 7 days max.) Calendar clock accuracy: Monthly deviation 2 minutes at 25°C Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (BACnet MS/TP to contact input to contact output to power to FE) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1, EN 61010-2-201 Measurement Category II (contact output) Installation Category II (power input) Pollution Degree 2 BACnet MS/TP to contact input to contact output to power: Reinforced insulation (300 V) RoHS Directive |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |