Back Button MAX20342 Datasheet HTML 17Page - Maxim Integrated Products MAX20342 Datasheet HTML 18Page - Maxim Integrated Products MAX20342 Datasheet HTML 19Page - Maxim Integrated Products MAX20342 Datasheet HTML 20Page - Maxim Integrated Products MAX20342 Datasheet HTML 21Page - Maxim Integrated Products MAX20342 Datasheet HTML 22Page - Maxim Integrated Products MAX20342 Datasheet HTML 23Page - Maxim Integrated Products MAX20342 Datasheet HTML 24Page - Maxim Integrated Products MAX20342 Datasheet HTML 25Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 91 page
background image
MAX20342
USB Type-C Charger Detector with
Integrated OVP
www.maximintegrated.com
Maxim Integrated | 21
Moisture Detection
The MAX20342 supports resistance measurement between selected pins on the USB Type-C connector. This
measurement can be used to determine if there is moisture or some other form of conductive debris present in the
connector. The moisture detection function can be automatically configured (MoistDetAutoCfg = 1) or manually configured
(MoistDetAutoCfg = 0) and also supports manual triggering (MoistDetManEn = 1) or periodic triggering (MoistDetPerEn
= 1). The moisture detection function is run only when the MAX20342 is not in shutdown mode and VB or a CC connection
has not been detected.
Moisture Detection Threshold RMOIST
The RMOIST is defined by the combination of the ADC voltage threshold RMoistDetVth[7:0] and the selected pullup current
RMoistDetIpu[1:0]. When the measured resistance is below RMOIST, the ResMoistInt interrupt is asserted. Since both the
voltage and current are needed to calculate resistance, the IpuResult[1:0] and ADCResultAvg[7:0] results are evaluated
together to determine if moisture is detected (measured resistance < RMOIST). Table 5 lists the conditions for the
indication of moisture. The resistance of the moisture threshold must be set with respect to the resistance constraints
listed in Table 7 and Table 8.
Table 5. Moisture Detection Result
IPURESULT[1:0]
ADCRESULTAVG[7:0]
MOISTURE DETECTED
(MEASURED RESISTANCE < RMOIST)
< RMoistDetIpu[1:0]
Don’t Care
No
== RMoistDetIpu[1:0]
< RMoistDetVth[7:0]
Yes
> RMoistDetIpu[1:0]
Don’t Care
Yes
Automatic Configuration
If the automatic configuration mode is selected (MoistDetAutoCfg = 1), all the pulldown and pullup switches described in
the Resistive Measurement section are automatically controlled during moisture detection. When an automatically
configured moisture detection is triggered either manually (MoistDetManEn = 1) or periodically (MoistDetPerEn = 1), the
resistance is measured between one of the CC pins and ground while all other USB Type-C pins (VB, CDP, CDN, SBU1,
SBU2, and the other CC) are grounded.
If the result is Open or Abort, the moisture detection ends, no interrupt is triggered, and the result is reported in
IpuResult[1:0] and ADCResultAvg[7:0]. If the result is a finite resistance above the moisture threshold defined by
RMoistDetVth[7:0] and RMoistDetIpu[1:0], the detection ends, ResFiniteInt interrupt is asserted, and the result is reported.
If the result is below the moisture threshold, ResMoistInt interrupt is asserted and a burst of consecutive resistive
measurements is performed on CC1/CC2/SBU1/SBU2 (pulled up one at a time) to ground while the other USB Type-C
pins are grounded. Finally, the burst measurement results are reported in the registers MoistDetAutoCC1/CC2Result1,
MoistDetAutoCC1/CC2Result2, MoistDetAutoSBU1/SBU2Result1, and MoistDetAutoSBU1/SBU2Result2. Figure 2
shows the detection flow for automatically configured moisture detection.
Automatically configured moisture detection always starts on the alternate CC pin when the next detection is triggered
either periodically or manually as shown in Figure 4.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com