21 / 91 page ![]() MAX20342 USB Type-C Charger Detector with Integrated OVP www.maximintegrated.com Maxim Integrated | 21 Moisture Detection The MAX20342 supports resistance measurement between selected pins on the USB Type-C connector. This measurement can be used to determine if there is moisture or some other form of conductive debris present in the connector. The moisture detection function can be automatically configured (MoistDetAutoCfg = 1) or manually configured (MoistDetAutoCfg = 0) and also supports manual triggering (MoistDetManEn = 1) or periodic triggering (MoistDetPerEn = 1). The moisture detection function is run only when the MAX20342 is not in shutdown mode and VB or a CC connection has not been detected. Moisture Detection Threshold RMOIST The RMOIST is defined by the combination of the ADC voltage threshold RMoistDetVth[7:0] and the selected pullup current RMoistDetIpu[1:0]. When the measured resistance is below RMOIST, the ResMoistInt interrupt is asserted. Since both the voltage and current are needed to calculate resistance, the IpuResult[1:0] and ADCResultAvg[7:0] results are evaluated together to determine if moisture is detected (measured resistance < RMOIST). Table 5 lists the conditions for the indication of moisture. The resistance of the moisture threshold must be set with respect to the resistance constraints listed in Table 7 and Table 8. Table 5. Moisture Detection Result IPURESULT[1:0] ADCRESULTAVG[7:0] MOISTURE DETECTED (MEASURED RESISTANCE < RMOIST) < RMoistDetIpu[1:0] Don’t Care No == RMoistDetIpu[1:0] < RMoistDetVth[7:0] Yes > RMoistDetIpu[1:0] Don’t Care Yes Automatic Configuration If the automatic configuration mode is selected (MoistDetAutoCfg = 1), all the pulldown and pullup switches described in the Resistive Measurement section are automatically controlled during moisture detection. When an automatically configured moisture detection is triggered either manually (MoistDetManEn = 1) or periodically (MoistDetPerEn = 1), the resistance is measured between one of the CC pins and ground while all other USB Type-C pins (VB, CDP, CDN, SBU1, SBU2, and the other CC) are grounded. If the result is Open or Abort, the moisture detection ends, no interrupt is triggered, and the result is reported in IpuResult[1:0] and ADCResultAvg[7:0]. If the result is a finite resistance above the moisture threshold defined by RMoistDetVth[7:0] and RMoistDetIpu[1:0], the detection ends, ResFiniteInt interrupt is asserted, and the result is reported. If the result is below the moisture threshold, ResMoistInt interrupt is asserted and a burst of consecutive resistive measurements is performed on CC1/CC2/SBU1/SBU2 (pulled up one at a time) to ground while the other USB Type-C pins are grounded. Finally, the burst measurement results are reported in the registers MoistDetAutoCC1/CC2Result1, MoistDetAutoCC1/CC2Result2, MoistDetAutoSBU1/SBU2Result1, and MoistDetAutoSBU1/SBU2Result2. Figure 2 shows the detection flow for automatically configured moisture detection. Automatically configured moisture detection always starts on the alternate CC pin when the next detection is triggered either periodically or manually as shown in Figure 4. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |