Electronic Components Datasheet Search
  English  ▼

X  

ISO7740 Datasheet(PDF) 3 Page - Texas Instruments

Click here to check the latest version.
Part # ISO7740
Description  ISO774x High-Speed, Robust-EMC Reinforced and Basic Quad-Channel Digital Isolators
PDF  52 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

ISO7740 Datasheet(HTML) 3 Page - Texas Instruments

  ISO7740 Datasheet HTML 1Page - Texas Instruments ISO7740 Datasheet HTML 2Page - Texas Instruments ISO7740 Datasheet HTML 3Page - Texas Instruments ISO7740 Datasheet HTML 4Page - Texas Instruments ISO7740 Datasheet HTML 5Page - Texas Instruments ISO7740 Datasheet HTML 6Page - Texas Instruments ISO7740 Datasheet HTML 7Page - Texas Instruments ISO7740 Datasheet HTML 8Page - Texas Instruments ISO7740 Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 52 page
background image
3
ISO7740, ISO7741, ISO7742
www.ti.com
SLLSEP4G – MARCH 2016 – REVISED FEBRUARY 2020
Product Folder Links: ISO7740 ISO7741 ISO7742
Submit Documentation Feedback
Copyright © 2016–2020, Texas Instruments Incorporated
•
Changed VIORM value for DW-16 package From: "1414 VPK" To: "2121 VPK" in Insulation Specifications table.................. 10
•
Changed VIOWM values for DW-16 package From: "1000 VRMS" and "1414 VDC" To: "1500 VRMS" and "2121 VDC" in
Insulation Specifications table ............................................................................................................................................. 10
•
Added 'see Figure 28' to TEST CONDITIONS of VIOWM specification in Insulation Specifications ...................................... 10
•
Changed VIOSM TEST CONDITIONS From: "Test method per IEC 60065" To: "Test method per IEC 62368-1" in
Insulation Specifications table .............................................................................................................................................. 10
•
Updated certification information in Safety-Related Certifications table .............................................................................. 11
•
Switched the line colors for VCC at 2.5 V and VCC at 3.3 V in Figure 12 .............................................................................. 21
•
Added Insulation Lifetime sub-section under Application Curve section.............................................................................. 31
•
Added 'How to use isolation to improve ESD, EFT, and Surge immunity in industrial systems' application report to
Documentation Support section ........................................................................................................................................... 34
Changes from Revision D (May 2017) to Revision E
Page
•
Changed the DIN certification number and certification status throughout the document ..................................................... 1
•
Changed the isolation rating of the DBQ package from 2500 VRMS to 3000 VRMS ................................................................. 1
•
Added VTEST to the conditions for the maximum transient isolation voltage parameter in the Insulation Specifications
table ...................................................................................................................................................................................... 10
•
Changed the value for the DBQ package from 3600 VPK to 4242 VPK throughout the document...................................... 10
•
Changed the method b1 Vini condition for apparent charge in the Insulation Specifications table ...................................... 10
•
Switched the labels for VCC1 falling and VCC2 rising in the graph legend of Power Supply Undervoltage Threshold vs
Free-Air Temperature ........................................................................................................................................................... 21
Changes from Revision C (December 2016) to Revision D
Page
•
Updated the Safety-Related Certifications table................................................................................................................... 11
•
Changed the minimum CMTI from 40 to 85 in all Electrical Characteristics tables ............................................................ 12
Changes from Revision B (October 2016) to Revision C
Page
•
Changed the Regulatory Information table to Safety-Related Certifications and updated content. ..................................... 11
•
Changed the certifications from planned to certified in the Safety-Related Certifications table........................................... 11
Changes from Revision A (June 2016) to Revision B
Page
•
Changed Feature From: High CMTI: ±75 kV/μs Typical To: High CMTI: ±100 kV/μs Typical ............................................... 1
•
Changed Feature From: All Certifications are Planned To: 'VDE, UL, and TUV Certifications for DW Package
Complete; All Other Certifications are Planned ...................................................................................................................... 1
•
Changed the unit value of CLR and CPG From: μm To: mm in Insulation Specifications................................................... 10
•
Changed From: "Plan to certify" To: "Certified" in column VDE of Safety-Related Certifications ........................................ 11
•
Added a conditions statement to Safety-Related Certifications .......................................................................................... 11
•
Changed From: "Plan to certify" To: "Certified" in column UL of Safety-Related Certifications ........................................... 11
•
Changed From: "Plan to certify" To: "Certified" in column TUV of Safety-Related Certifications ........................................ 11
•
Changed From: "Certification Planned" To: 'Certificate number: 40040142" in column VDE of Safety-Related
Certifications ......................................................................................................................................................................... 11
•
Changed From: "Certification Planned" To: "File number: E181974" in column VDE of Safety-Related Certifications....... 11
•
Changed From: "Certification Planned" To: "Client ID number: 77311" in column TUV of Safety-Related Certifications ... 11
•
Changed the CMTI TYP value From: 75 kV/μs To: 100 kV/μs in the Electrical Characteristics—5-V Supply ..................... 12
•
Changed the CMTI TYP value From: 75 kV/μs To: 100 kV/μs in the Electrical Characteristics—3.3-V Supply .................. 14
•
Changed the CMTI TYP value From: 75 kV/μs To: 100 kV/μs in the Electrical Characteristics—2.5-V Supply .................. 16



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com