Back Button ML2302 Datasheet HTML 11Page - OKI electronic componets ML2302 Datasheet HTML 12Page - OKI electronic componets ML2302 Datasheet HTML 13Page - OKI electronic componets ML2302 Datasheet HTML 14Page - OKI electronic componets ML2302 Datasheet HTML 15Page - OKI electronic componets ML2302 Datasheet HTML 16Page - OKI electronic componets ML2302 Datasheet HTML 17Page - OKI electronic componets ML2302 Datasheet HTML 18Page - OKI electronic componets ML2302 Datasheet HTML 19Page - OKI electronic componets Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 24 page
background image
FEDL2302DIGEST-05
OKI Semiconductor
ML2302
15/24
READING STATUS
The ML2302 supports the following seven status flags.
Table 4.1
Pin
Status
Description
D7
Data Recording/Playing flag
High when recording or playback is in progress
D6
Don’t Care
D5
Pause flag
High when playback of left voice is paused
D4
Don’t Care
D3
EMP Information Output flag
Output the same signal as the EMP pin. Note)
D2
MID Information flag
Output the same signal as the MID pin. Note)
D1
FUL Information flag
Output the same signal as the FUL pin. Note)
D0
Data Transfer Error flag
See “Data Transfer Errors”.
Note:
EM, MID, and FUL are either at the active “H” or at the active “L” by setting the signal output format by
the command. The status signals on D3 to D1 are determined depending on the status of the FIFOST pin as
shown below.
FIFOST = “0”
FIFOST = “1”
D3
EMP signal for playback FIFO
EMP signal for recording FIFO
D2
MID signal for playback FIFO
MID signal for recording FIFO
D1
FUL signal for playback FIFO
FUL signal for recording FIFO
Data Transfer Errors
The Data Transfer flag supports the following four errors.
(1) “H” when data is read while EMP for recording FIFO is “H”
(2) “H” when data is written while FUL for playback FIFO is “H”
(3) “H” when a command is written while
CBUSY is “L”.
(4) “H” when recording data cannot be written in FIFO while FUL for recording FIFO is “H”.
*These four errors are released when a normal transfer described below is carried out.
(1) Reads data while EMP for recording FIFO is “L”.
(2) Writes data while FUL for playback FIFO is “L”.
(3) Writes a command while
CBUSY is “H”.
(4) The error flag is released when data is written in recording FIFO within LSI after reading data from recording
FIFO and setting FUL for recording FIFO to “L”.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com