Electronic Components Datasheet Search
  English  ▼

X  

IRC40 Datasheet(PDF) 6 Page - Carlo Gavazzi Holding AG

Part # IRC40
Description  Proximity inductive sensors with rectangular housing and 5 positions rotatable head
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  CARLOGAVAZZI [Carlo Gavazzi Holding AG]
Direct Link  https://gavazziautomation.com/
Logo CARLOGAVAZZI - Carlo Gavazzi Holding AG

IRC40 Datasheet(HTML) 6 Page - Carlo Gavazzi Holding AG

Back Button IRC40 Datasheet HTML 2Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 3Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 4Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 5Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 6Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 7Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 8Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 9Page - Carlo Gavazzi Holding AG IRC40 Datasheet HTML 10Page - Carlo Gavazzi Holding AG Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 16 page
background image
6
Carlo Gavazzi Automation
IRC40
IRC40_4-wire_DC_DS_EN
04/07/2022
Features
Power Supply
Rated operational voltage (U
b)
10 to 30 VDC (ripple included)
Ripple (U
rpp)
≤ 10%
No load supply current (I
o)
≤ 20 mA
Power ON delay (t
v)
≤ 50 ms
Outputs
Output functions
NPN or PNP by sensor type open collector
Output configuration
N.O. and N.C.
Output current (I
e)
≤ 200 mA
OFF-state current (I
r)
≤ 100 μA
Voltage drop (U
d)
Max. 2.5 VDC @ 200 mA
Protection
Short-circuit, reverse polarity and overload
Voltage transient
1 kV/0.5 J
Response times
Operating frequency (f)
≤ 200 Hz
Indication
Green LED
Yellow LED
Output
Description
ON
OFF
OFF
Target not present
ON
ON
ON
Target present
-
Blinking
f: 2Hz
Short-circuit or overload
Environmental
Ambient temperature
Operating: -25° to +80°C (-13° to +176°F)
Storage: -25° to +80°C (-13° to +176°F)
Ambient humidity
Operating: 35% to 95%
Storage: 35% to 95%
Vibration
10 to 55 Hz, amplitude 1.0 mm; sweep cycle 5
min; in X, Y and Z direction
EN 60068-2-6
Shock
30 G /11 ms. 10 shocks in X, Y and Z direction
EN 60068-2-27
Rough handling shocks
2 times from 1m, 100 times from 0.5m
EN 60068-2-31
Degree of protection
IP67, IP68 (1m submersion for 24h), IP69K
IEC 60529; EN 60947-1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com