| Electronic Components Datasheet Search |
|
STBVR81 Datasheet(PDF) 5 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
STBVR81 Datasheet(HTML) 5 Page - Banner Engineering Corp. |
|
5 / 12 page ![]() K the EN 13855 recommended hand-speed constant (in millimeters per second), in most cases is calculated at 1600 mm/s, but may vary between 1600 mm/s to 2500 mm/s based on the application circumstances; not a conclusive determination; consider all factors, including the physical ability of the operator, when determining the value of K to be used. T the overall machine stopping response time (in seconds), from the physical initiation of the safety device to the final ceasing of all motion. C the added distance due to the depth penetration factor equals 250 mm, per EN 13855. The EN 13855 C factor may be reduced to 0 if the risk of encroachment is eliminated, but the safety distance must always be 100 mm or greater. Example Separation Distance Calculation The following example illustrates the use of the formula to calculate separation distance for a part-revolution clutch machine. This example uses 0.50 seconds as a typical value for Ts and 0.035 seconds for Tr and 0.020 seconds for Th: K = 63 in per second, Ts = 0.50 seconds (measured by a stop-time measuring device) Tr = 0.035 seconds Th = 0.020 seconds Ds = K × (Ts + Tr + Th) = 63 in (0.50 + 0.035 + 0.020) = 35 in In this example, both hand controls must be located no closer than 35 in from the nearest hazard point. Wiring Diagrams Cabled models only are shown. Quick-disconnect wiring is functionally identical. Connection of DC power is without regard to polarity. Electromechanical Relay Output Models PNP (Sourcing) Solid-State Output Models Wiring Key 1 3 2 5 4 Supply Voltage* (see Specifications) N.C. C N.O. * NOTE: Connection of dc power is without regard to polarity. 3 1 4 2 10-30V dc – + Load Load 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray or Yellow Figure 3. Generic interface of a relay-output STB Touch Button to a type IIIC two-hand-control module A 1 K 1 K 2 Inputs Inputs MPCE Feedback A 2 A 1 A 2 A 1 A 2 Machine Control Circuit Two-Hand Control Type IIIC MPCE 1 MPCE 2 Wiring Key 1 = Two-Hand Control Type IIIC Module 2 = Inputs 3 = MPCE feedback 4 = Machine control circuit STB Self-Checking Optical Touch Buttons P/N 64136 Rev. F www.bannerengineering.com - Tel: + 1 888 373 6767 5 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |