Back Button STBVR81 Datasheet HTML 3Page - Banner Engineering Corp. STBVR81 Datasheet HTML 4Page - Banner Engineering Corp. STBVR81 Datasheet HTML 5Page - Banner Engineering Corp. STBVR81 Datasheet HTML 6Page - Banner Engineering Corp. STBVR81 Datasheet HTML 7Page - Banner Engineering Corp. STBVR81 Datasheet HTML 8Page - Banner Engineering Corp. STBVR81 Datasheet HTML 9Page - Banner Engineering Corp. STBVR81 Datasheet HTML 10Page - Banner Engineering Corp. STBVR81 Datasheet HTML 11Page - Banner Engineering Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 12 page
background image
Specifications
Supply Voltage and Current
STBVP6 models: 10 V DC to 30 V DC at 75 mA, typical
STBVR81 models: 20 V AC/DC to 30 V AC/DC or 20 V AC to 30 V AC
(peak-to-peak value), (50/60 Hz ±5%) at 75 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
STBVP6 models: Complementary PNP (sourcing) open-collector transistors
STBVR81 models: Complementary electromechanical relays
Output Rating
STBVP6 models (solid-state outputs):
Max. load: 150 mA
On-state max. output voltage (no load): +V(supply) − 1.5 V
Off-state leakage current: < 1 μA
STBVR81 models (electromechanical relays):
Max. switching voltage: 125 V DC/150 V AC
Max. switching current: 1 A @at 24 V DC; 0.4 A at 125 V AC (resistive
loads)
Max. resistive power: 24 W DC/50 VA AC
Mechanical life of relays: 109 cycles
Electrical life of relays: 1.5 x 105 cycles at 1 amp, 24 V resistive
Output Protection Circuitry
All models protected against false pulse on power-up. Models with solid-state
outputs have overload and short-circuit protection.
Output Response Time
20 milliseconds ON/OFF
Indicators
2 green LED indicators:
Power: ON – power applied
Output/fault: ON – button is activated; OFF – button is deactivated;
Flashing – internal fault or blocked button on power-up detected
Connections
PVC-jacketed 2 m (6.5 ft) cables or quick disconnect fitting, depending on
model; integral 9 m (30 ft) cables are also available. Accessory cables
required for quick disconnect models.
STBVP6 models: 4-wire (4-pin 7/8 in-16UNF or M12 quick disconnect)
STBVR81 models: 5-wire (5-pin 7/8 in-16UNF or M12 quick disconnect)
Environmental Rating
Meets NEMA 1, 3, 4, 4X, 12 and 13; IP66
Construction
Totally encapsulated, non-metallic enclosure. Black polyetherimide upper
housing; fiber-reinforced PBT polyester base. Electronics fully
epoxyencapsulated. Pre-installed polypropylene (TP) protective field cover.
Ambient Light Immunity
Up to 100,000 lux
Applicable Application Standards
The STB Self-Checking Optical Touch Buttons meet the requirements of Cat.
4/PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 62061/IEC 61508
when interfaced with a IIIC Two-Hand Control Module (for example, AT-
FM-10K or an appropriate Safety Controller (for example, XS/SC26, SC10-2)
configured as a IIIC Two-Hand Control system in order to be used in safety
applications.
Operating Conditions
0 °C to +50 °C (+32 °F to +122 °F)
90% at +50 °C maximum relative humidity (non-condensing)
Application Notes
The polyetherimide upper housing will become brittle with prolonged
exposure to outdoor sunlight. Window glass effectively filters longer
wavelength ultraviolet light and provides excellent protection from sunlight.
Avoid contact with strong alkalis, hydrocarbons and fuels. Clean periodically
using mild soap solution and a soft cloth.
Two-Hand Control System Note
When STBVP6 buttons are used with Two-Hand Control Modules or Safety
Controllers (for example, XS/SC26-2, SC10-2) in a IIIC two-hand control
system, the power supply to the STBVP6 buttons must be of the same
voltage that is used to power the Two-Hand Control Module/Safety Controller
and they must have a common supply return (that is, 0 V or ground).
Certifications
STB Self-Checking Optical Touch Buttons
P/N 64136 Rev. F
www.bannerengineering.com - Tel: + 1 888 373 6767
7



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com