32 / 43 page ![]() AS3682 austriamicrosystems Data Sheet Power-On Reset www.austriamicrosystems.com Revision 2.21 32 - 43 11.7 Power-On Reset The internal reset is controlled by two inputs: ! VBAT1 Supply ! VDD_GPIO If either of these voltages is lower than their limit, an internal reset is forced. The reset levels control the state of all registers. As long as VBAT and VDD_GPIO are below their reset thresholds, the register contents are set to default. Access by serial interface is possible once the reset thresholds are exceeded. Note: VVDD_GPIO_TH – Use rising or falling threshold levels, depending on the slope of VDD_GPIO (power up/power down). 11.8 Temperature Supervision An integrated temperature sensor provides over-temperature protection for the AS3682. This sensor generates a flag if the device temperature reaches the over-temperature threshold (T140 page 8). The threshold has a hysteresis (T140 page 8) to prevent oscillation effects. If the device temperature exceeds the T140 threshold, the current sources are switched off, and bit ov_temp in register Overtemp_control (page 32) is set to 1. After decreasing the temperature by THYST, the current sources resume operation. The ov_temp flag will only be reset (by the circuit when the temperature has reached operating condition again) after the software has written a 1 and then a 0 to bit rst_ov_temp (page 32). Bit ov_temp_on activates temperature supervision. Table 32. Reset Control Reset Control Register State (All Registers) VBAT < VPOR_VBAT and VVDD_GPIO < VGPIO_VDD_TH Undefined VBAT < VPOR_VBAT and VVDD_GPIO > VGPIO_VDD_TH Undefined VBAT > VPOR_VBAT and VVDD_GPIO < VGPIO_VDD_TH Default VBAT > VPOR_VBAT and VVDD_GPIO > VGPIO_VDD_TH Default Access by serial interface possible. Table 33. Overtemperature Bit Definitions Addr: 0E Overtemp_control This register reads and resets the overtemperature flag. Bit Bit Name Default Access Description 0 ov_temp_on 1R/W Activates/deactivates device temperature supervision. 0 = Temperature supervision is disabled. No current source will be switched off if the device temperature exceeds the over-temperature rising threshold (T140). 1 = Temperature supervision is enabled. 1 ov_temp NA R 1 = Indicates that the over-temperature rising threshold (T140) has been reached. To clear this flag, it is mandatory to use bit rst_ov_temp. Bit ov_temp is only active if temperature supervision is activated. 2 rst_ov_temp NA R/W The ov_temp flag is cleared by first setting this bit to 1, and then setting this bit to 0. Bit rst_ov_temp is only active if temperature supervision is activated. 7:3 N/A |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |