| Electronic Components Datasheet Search |
|
TRACERDAQPRO Datasheet(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
TRACERDAQPRO Datasheet(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 7 page ![]() Measurement Computing (508) 946-5100 2 info@mccdaq.com mccdaq.com USB-1602HS and USB-1604HS Series Counter Input USB-1602HS and USB-1604HS Series devices have four counters that accept frequency inputs up to 20 MHz. The counter chan- nels can be read as 16-bit or 32-bit counters. The default input type is TTL, rising-edge triggered. Counters can be used to concurrently monitor time periods, fre- quencies, pulses, and other event-driven incremental operations. Users can map counter channels to gate a counter, decrement a counter, or latch the current count to the count register. Users can also configure a counter to be gated by another counter input that is mapped as a gate input. Counters can be read asynchronously under program control, or synchronously as part of an analog or digital scan group. • When read synchronously, all counters are set to zero at the start of an acquisition. • When read asynchronously, counters may be cleared on each read, count up continually, or count until the 16-bit or 32-bit limit is reached. Counter, period, pulse width measurement (PWM), and timing counter modes are supported. Quadrature Encoders Users can connect up to three quadrature encoders to measure linear and rotary position. Encoders with a 16-bit (counter low) or a 32-bit (counter low and counter high) counter, 6 MHz maximum pulse frequency, and X1, X2, and X4 count modes are supported. Each input can be debounced to eliminate noise or false edges, or to switch induced transients. Trigger Input The USB-1602HS and USB-1604HS Series supports hardware and software triggering. With hardware-based triggers, an output value is compared in hardware to an input level on a specified channel. These hardware-based triggers are supported: • Analog input hardware • External digital trigger input (DIG TRIG pin) With software-based triggers, an analog, digital, or counter reading is checked by the computer in order to detect a trigger event. These software-based triggers are supported: • Analog software trigger • Digital pattern • Counter/totalizer These software triggers can also be used to stop an acquisition. Features Timer Output The USB-1602HS and USB-1604HS Series have two timer outputs for generating pulse width waves. The duty cycle and frequency are software-selectable. Timer outputs can be updated asynchro- nously at any time. Clock I/O The USB-1602HS and USB-1604HS Series have independent input and output pacing clocks. Users can pace analog, digital, and counter input scans with the internal input clock or an external clock. Analog channels can be paced from 0.75 µs to 1000 seconds in 20.83 ns steps. Digital and counter inputs can be paced from 250 ns to 1 second in 20.83 ns steps. The clock rate is 8 MHz maximum for both the internal input clock and external input clock. Users can pace analog, digital, and timer output operations with the internal input clock, internal output clock, external input clock, or external output clock. The clock rate is 1 MHz maximum for analog output operations, and 8 MHz maximum for digital operations with no analog channels enabled. Setpoint Detection Users can configure a detection setpoint for each analog input channel. Setpoint detection can be used to update an output channel with an input channel value, or to write a specified value to a digital output port, when specified criteria is met. This allows for real-time control based on acquisition data. Setpoint detection criteria is configurable with software. Signal Connections A 68-pin SCSI connector provides connections for all signal I/O except analog inputs. BNC connectors provide connections for the analog inputs, and alternate connections for the external clock and external digital trigger input. Calibration USB-1602HS and USB-1604HS Series devices are factory-calibrat- ed using a NIST-traceable calibration process. Correction factors for each range are stored on the device at the time of calibration. Specifications are guaranteed for one year. For calibration beyond one year, return the device to the factory for recalibration. USB-1602HS and USB-1604HS Series devices support field calibra- tion. Field calibration traceability is derived through the onboard reference. Use the InstaCal utility to calibrate the device after it has fully warmed up and immediately before making critical measurements. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |