| Electronic Components Datasheet Search |
|
AD71056 Datasheet(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD71056 Datasheet(HTML) 13 Page - Analog Devices |
|
13 / 20 page ![]() AD71056 Rev. A | Page 13 of 20 POWER SUPPLY MONITOR The AD71056 contains an on-chip power supply monitor. The power supply (VDD) is continuously monitored by the AD71056. If the supply is less than 4 V, the AD71056 becomes inactive. This is useful to ensure proper device operation at power-up and power-down. The power supply monitor has built-in hysteresis and filtering that provide a high degree of immunity to false triggering from noisy supplies. In Figure 21, the trigger level is nominally set at 4 V. The tolerance on this trigger level is within ±5%. The power supply and decoupling for the part should be such that the ripple at VDD does not exceed 5 V ± 5% as specified for normal operation. VDD 5V 4V 0V TIME INACTIVE ACTIVE INACTIVE INTERNAL ACTIVATION Figure 21. On-Chip Power Supply Monitor HPF and Offset Effects Figure 22 illustrates the effect of offsets on the real power calculation. As can be seen, offsets on Channel V1 and Channel V2 contribute a dc component after multiplication. Because this dc component is extracted by the LPF and used to generate the real power information, the offsets contribute a constant error to the real power calculation. This problem is easily avoided by the built-in HPF in Channel V1. By removing the offsets from at least one channel, no error component can be generated at dc by the multiplication. Error terms at the line frequency (ω) are removed by the LPF and the digital-to- frequency conversion (see the Digital-to-Frequency Conversion section). DC COMPONENT (INCLUDING ERROR TERM) IS EXTRACTED BY THE LPF FOR REAL POWER CALCULATION IOS × V VOS × I VOS × IOS V× I 2 0 FREQUENCY (RAD/s) Figure 22. Effect of Channel Offset on the Real Power Calculation Equation 6 shows how the power calculation is affected by the dc offsets in the current and voltage channels. ( ) { } ( ) { } OS OS I t I V t V + ω × + ω cos cos (6) () ( ) t V I t I V I V I V OS OS OS OS ω × + ω × + × + × = cos cos 2 () t I V ω × × + 2 cos 2 The HPF in Channel V1 has an associated phase response that is compensated for on chip. Figure 23 and Figure 24 show the phase error between channels with the compensation network activated. The AD71056 is phase compensated up to 1 kHz as shown. This ensures correct active harmonic power calculation even at low power factors. FREQUENCY (Hz) 0.30 0.25 0.20 0.15 0.10 0.05 0 –0.05 –0.10 0 100 200 300 400 500 600 700 800 900 1000 Figure 23. Phase Error Between Channels (0 Hz to 1 kHz) FREQUENCY (Hz) 0.30 0.25 0.20 0.15 0.10 0.05 0 –0.05 –0.10 40 45 50 55 60 65 70 Figure 24. Phase Error Between Channels (40 Hz to 70 Hz) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |