AD71056 Datasheet(PDF) 16 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD71056 Datasheet(HTML) 16 Page - Analog Devices |
|
16 / 20 page ![]() AD71056 Rev. A | Page 16 of 20 Table 6. Maximum Output Frequency on the F1 and F2 Pins S1 S0 OSC Relation Max Frequency1 or AC Inputs (Hz) 0 0 0.204 × f1 0.175 0 1 0.204 × f2 0.35 1 0 0.204 × f3 0.70 1 1 0.204 × f4 1.40 1 Values are generated using the nominal frequency of 450 kHz. Frequency Output CF The Pulse Output CF (calibration frequency) is intended for calibration purposes. The output pulse rate on CF can be up to 2048 times the pulse rate on the F1 and F2 pins. The lower the f1…4 frequency selected, the higher the CF scaling (except for the high frequency mode where SCF = 0, S1 = S0 = 1). Table 7 shows how the two frequencies are related, depending on the states of the logic inputs (S0, S1, and SCF). Due to its relatively high pulse rate, the frequency at the CF logic output is proportional to the instantaneous real power. As with F1 and F2, CF is derived from the output of the low-pass filter after multiplication. However, because the output frequency is high, this real power information is accumulated over a much shorter time. Therefore, less averaging is carried out in the digital-to- frequency conversion. With much less averaging of the real power signal, the CF output is much more responsive to power fluctuations (see the signal processing block in Figure 15). Table 7. Maximum Output Frequency on CF SCF S1 S0 CF Max for AC Signals (Hz)1 1 0 0 128 × F1, F2 = 22.4 0 0 0 64 × F1, F2 = 11.2 1 0 1 64 × F1, F2 = 22.4 0 0 1 32 × F1, F2 = 11.2 1 1 0 32 × F1, F2 = 22.4 0 1 0 16 × F1, F2 = 11.2 1 1 1 16 × F1, F2 = 22.4 0 1 1 2048 × F1, F2 = 2.867 kHz 1 Values are generated using the nominal frequency of 450 kHz. SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As listed in Table 5, the user can select one of four frequencies. This frequency selection determines the maximum frequency on the F1 and F2 pins. These outputs are intended for driving an energy register (electromechanical or other). Because only four different output frequencies can be selected, the available frequency selection is optimized for a meter constant of 100 imp/kWh with a maximum current between 10 A and 120 A. Table 8 shows the output frequency for several maxi- mum currents (IMAX) with a line voltage of 220 V. In all cases, the meter constant is 100 imp/kWh. Table 8. F1 and F2 Frequency at 100 imp/kWh IMAX (A) F1 and F2 (Hz) 12.5 0.076 25.0 0.153 40.0 0.244 60.0 0.367 80.0 0.489 120.0 0.733 The f1…4 frequencies allow complete coverage of this range of output frequencies (F1, F2). When designing an energy meter, the nominal design voltage on Channel V2 (voltage) should be set to half-scale to allow for calibration of the meter constant. The current channel should also be no more than half-scale when the meter sees maximum load. This allows overcurrent signals and signals with high crest factors to be accommodated. Table 9 lists the output frequency on the F1 and F2 pins when both analog inputs are half-scale. The frequencies listed in Table 9 align very well with those listed in Table 8 for maximum load. Table 9. F1 and F2 Frequency with Half-Scale AC Inputs S1 S0 f1…4 (Hz) Frequency on F1 and F2— CH1 and CH2 Half-Scale AC Input1 0 0 0.86 0.051 × f1 0.044 Hz 0 1 1.72 0.051 × f2 0.088 Hz 1 0 3.43 0.051 × f3 0.176 Hz 1 1 6.86 0.051 × f4 0.352 Hz 1 Values are generated using the nominal frequency of 450 kHz. When selecting a suitable f1…4 frequency for a meter design, compare the frequency output at IMAX (maximum load) based on a meter constant of 100 imp/kWh against the last column of Table 9. The closest frequency in Table 9 determines the best choice of frequency (f1…4). For example, if a meter with a maximum current of 25 A is being designed, the output frequency on the F1 and F2 pins with a meter constant of 100 imp/kWh is 0.153 Hz at 25 A and 220 V (from Table 8). In the last column of Table 9, the closest frequency to 0.153 Hz is 0.176 Hz. Therefore, f3 (3.43 Hz) is selected for this design (see Table 5). Frequency Outputs Figure 2 shows a timing diagram for the various frequency outputs. The outputs (F1 and F2) are the low frequency outputs that can be used to directly drive a stepper motor or electro- mechanical impulse counter. The F1 and F2 outputs provide two alternating low frequency pulses. The F1 and F2 pulse widths (t1) are set such that if they fall below 240 ms (0.24 Hz), they are set to half of their period. The maximum output frequencies for F1 and F2 are shown in Table 6. The high frequency CF output is intended to be used for communications and calibration purposes. CF produces a 90-ms-wide active high pulse (t4) at a frequency proportional |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |