| Electronic Components Datasheet Search |
|
OPA863DBVR Datasheet(PDF) 27 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
OPA863DBVR Datasheet(HTML) 27 Page - Texas Instruments |
|
27 / 52 page ![]() 9.2.4 Variable Reference Generator Using MDAC High-speed amplifiers can be used as a voltage buffer at MDAC output to generate a fast-settling variable reference voltage. Figure 9-5 shows a representative circuit using DAC8801 and OPAx863. DAC8801 + – I OUT R FB V REF V DD +6 V 6 V OPAx863 V OUT Figure 9-5. Variable Reference Generator Using MDAC and OPAx863 9.2.5 Clamp-On Ultrasonic Flow Meter Figure 9-6 shows how ultrasonic flow meters measure the rate of flow of a liquid using transit-time difference (t12–t21), which depends on the flow rate. Figure 9-6 shows a representative schematic for a non-intrusive ultrasonic flow meter using the OPAx863 and 12-V transducer excitation. The OPAx863 are used for the forward path as a unity-gain buffer for 12-V pulsed transducer excitation at NODE 1. At the same time, the receiver circuit at NODE 2 (which also uses the OPAx863) first provides an ac-gain followed by a dc-level shift to lead to the PGA, ADC, and processor within the MSP430™ microcontroller. NODE 2 and NODE 1 use similar transmit and receive circuits (discussed previously) for the reverse path. The OPAx863 wide GBW of 50 MHz introduces minimal phase-delay and low-noise for excellent flow rate measurement. The amplifier stays in power-down mode for a majority of the time in battery-powered systems. This configuration results in very small average system-level power consumption and prolonged battery lifetime with the 1.5 ‑µA (maximum) power-down mode quiescent current with a 3-V supply. The transmit and receive signal chains are connected to the same point at the respective node transducers. Therefore, the OPAx863 12.6-V supply voltage capability enables 12-V transducer excitation without any damage to the front-end, or a need for external switches, thus enabling a more compact solution. These specifications make the OPAx863 an excellent choice for flow measurements in large diameter pipes and non-intrusive flow meters. The TIDM-02003 reference design discusses an ultrasonic gas flow sensing subsystem which uses high-speed amplifiers for front-end amplification. TR X1 + ± OP Ax863 12 V R ISO + ± R F R G C G C Filt C AC2 R¶ R¶ 3.3 V PGA ADC MSP430FR6043 OP Ax863 TR X2 Processor Transmitter Receiver Receiver Transmitter NODE-1 NODE-2 3.3 V 12 V 0 V 12 V V TX 0 V 12 V V TX V R X V R X t 12 t 21 R R C AC1 12 V Figure 9-6. Non-Intrusive Ultrasonic Flow Meter www.ti.com OPA863, OPA2863, OPA4863 SBOS982J – JUNE 2020 – REVISED JUNE 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 27 Product Folder Links: OPA863 OPA2863 OPA4863 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |