Back Button MIC23350 Datasheet HTML 9Page - Microchip Technology MIC23350 Datasheet HTML 10Page - Microchip Technology MIC23350 Datasheet HTML 11Page - Microchip Technology MIC23350 Datasheet HTML 12Page - Microchip Technology MIC23350 Datasheet HTML 13Page - Microchip Technology MIC23350 Datasheet HTML 14Page - Microchip Technology MIC23350 Datasheet HTML 15Page - Microchip Technology MIC23350 Datasheet HTML 16Page - Microchip Technology MIC23350 Datasheet HTML 17Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 28 page
background image
 2019 Microchip Technology Inc.
DS20006126A-page 13
MIC23350
3.7
Enable Pin (EN)
The logic high enables the operation of the regulator.
The logic low shuts down the device. In the Off state,
the supply current of the device is greatly reduced (typ-
ically 1.5 µA). The EN pin should not be left open.
3.8
Power Good Pin (PG)
This is an open drain output that indicates when the
output voltage is higher than the 91% limit. There is a
4% hysteresis, therefore PG will return low when the
falling output voltage falls below 87% of the target reg-
ulation voltage.
3.9
Output Voltage Sense Pin (VOUT)
This pin is used to remote sense the output voltage.
Connect to VOUT as close to the output capacitor as
possible to sense the output voltage. It also provides
the path to discharge the output through an internal
10
 resistor when the device is disabled.
3.10
Analog Ground Pin (AGND)
Internal signal ground for all low-power circuits.
Connect to ground plane. For best load regulation, the
connection path from AGND to the output capacitor
ground terminal should be free from parasitic voltage
drops.
3.11
PGND Exposed Pad (PGND)
It is electrically connected to PGND pins. It must be
connected with thermal vias to the ground plane to
ensure adequate heat sinking. See Section 6.0,
Packaging Information.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com