31 / 100 page ![]() Miniatur e cir cuit br eakers S200 Low Voltage Products & Systems 15.29 ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 15 15 K S281UC-K S282UC-K S283UC-K No. of poles Rated current Catalog number No. of poles Rated current Catalog number 1 0,2 S281UC-K0.2 3 0.2 S283UC-K0.2 0,3 S281UC-K0.3 0.3 S283UC-K0.3 0,5 S281UC-K0.5 0.5 S283UC-K0.5 0,75 S281UC-K0.75 0.75 S283UC-K0.75 1 S281UC-K1 1 S283UC-K1 1,6 S281UC-K1.6 1.6 S283UC-K1.6 2 S281UC-K2 2 S283UC-K2 3 S281UC-K3 3 S283UC-K3 4 S281UC-K4 4 S283UC-K4 6 S281UC-K6 6 S283UC-K6 8 S281UC-K8 8 S283UC-K8 10 S281UC-K10 10 S283UC-K10 16 S281UC-K16 16 S283UC-K16 20 S281UC-K20 20 S283UC-K20 25 S281UC-K25 25 S283UC-K25 32 S281UC-K32 32 S283UC-K32 40 S281UC-K40 40 S283UC-K40 50 S281UC-K50 50 S283UC-K50 63 S281UC-K63 63 S283UC-K63 2 0,2 S282UC-K0.2 0,3 S282UC-K0.3 0,5 S282UC-K0.5 0,75 S282UC-K0.75 1 S282UC-K1 1,6 S282UC-K1.6 2 S282UC-K2 3 S282UC-K3 4 S282UC-K4 6 S282UC-K6 8 S282UC-K8 10 S282UC-K10 16 S282UC-K16 20 S282UC-K20 25 S282UC-K25 32 S282UC-K32 40 S282UC-K40 50 S282UC-K50 63 S282UC-K63 S201DC S282UC 500 VDC Two Pole LOAD 3+ 4- S280UC-K, 500 VDC Supplemental protectors UL 1077, CSA 22.2, No. 235 Tripping characteristic K UL 1077 250/500 VDC 10 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformer Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 Direct current applications The S280UC differs from standard minia- ture circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown. Termination points are marked on all UC type MCBs, points one (1) and four (4) are negative and points two (2) and three (3) are positive. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |