ICM7170AIPG Datasheet(PDF) 12 Page - Intersil Corporation |
|
|
|||||||||||||||||||||||||||||
ICM7170AIPG Datasheet(HTML) 12 Page - Intersil Corporation |
|
12 / 14 page ![]() 12 General Notes 1.TIME ACCESS - To update the present time registers (Hex 00 - 07) the 1/100 register must be read first. The 7 real time counter registers (Hours, Minutes, Seconds, Month, Date, Day, and Year) data are latched only if the 1/100 second counter register is read. The 1/100 seconds data itself is not latched. The real time data will be held in the latches until the 1/100 seconds is read again. See the data sheet section on LATCHED DATA. None of the RAM data is latched since it is static by nature. 2. REGULATED OSClLLATOR - The oscillator’s power supply is voltage regulated with respect to VDD. In the 32kHz mode the regulator’s amplitude is ∑VTN + VTP (≅1.8V). In the 1, 2, and 4MHz mode the regulator’s amplitude is ∑V TN + VTN + VTP ( ≅2.6V). As a result, signal conditioning is necessary to drive the oscillator with an external signal. In addition, it is also necessary to buffer the oscillator’s signal to drive other external clocks because of its reduced amplitude and offset voltage. 3. INTERNAL BATTERY BACKUP - When the ICM7170 is using its own internal battery backup circuitry, no other circuitry interfaced to the ICM7170 should be active during standby operation. When VDD (+5V) is turned off (Standby operation), VDD should equal VSS = 0V. All ICM7170 I/O should also equal VSS. At this time, the VBACKUP pin should be 2.8V to 3.5V below VSS when using a Lithium battery. 4. EXTERNAL BATTERY BACKUP - The ICM7170 may be placed on the same power supply as battery-backed up RAM by keeping the ICM7170 in its operational state and having an external circuit switch between system and backup power for the ICM7170 and the RAM. In this case VBACKUP should be pulled up to VDD through a 2K resistor. Although the ICM7170 is always “on” in this configuration, its current consumption will typically be less than a microamp greater than that of standby operation at the same supply voltage (See Note 9). Proper consideration must be given to disabling the ICM7170s and the RAMs I/O before system power is removed. This is important because many microprocessors can generate spurious write signals when their supply falls below their specified operating voltage limits. NANDing CS (or WR) with a POWERGOOD signal will create a CS (or WR) that is only valid when system power is within specifications. The POWERGOOD signal should be generated by an accurate supply monitor such as the ICL7665 under/over voltage detector. An alternate method of disabling the ICM7170’s I/O is to pull VBACKUP down to under a volt above VSS (VSS < VBACKUP <1.0V). This will cause the ICM7170 to internally disable all I/O. Do not allow VBACKUP to equal VSS, since this could cause oscillation of the battery backup comparator (See Figure 6). VBACKUP = VSS + 0.5V will disable the I/O and provide enough overdrive for the comparator. 5. ICM7170A PART - The ICM7170A part is binned at final test for a 32.768kHz maximum current of 5 µA. All other specifications remain the same. 6. INTERRUPTS - The Interrupt Status Register (address 10H) always indicates which of the real time counters have been incremented since the last time the register was read. NOTE: This is independent of whether or not any mask bits are set. The status register is always reset immediately after it is read. If an interrupt from the ICM7170 has occurred since the last time the status register was read, bit D7 of the register will be set. If the source was an alarm interrupt, bit D0 will also be set. If the interrupt transistor has been turned on, reading the Interrupt Status Register will reset it. To enable the periodic interrupt, both the Command Register’s Interrupt Enable bit (D4) and at least one bit in the Interrupt Mask Register (D1 - D6) must be set to a 1. The periodic inter- rupt is triggered when the counter corresponding to a mask bit that has been set is incremented. For example, if you enable the 1 second interrupt when the current value in the 100ths counter is 57, the first interrupt will occur 0.43 seconds later. All subsequent interrupts will be exactly one second apart. The interrupt service routine should then read the Interrupt Status Register to reset the interrupt transistor and, if necessary, determine the cause of the interrupt (periodic, alarm, or non- ICM7170 generated) from the contents of the status register. To enable the alarm interrupts, both the Command Register’s Interrupt Enable bit (D4) and the Interrupt Mask Register’s Alarm bit (D0) must be set to a 1. Each time there is an exact match between the values in the alarm register and the values in the real time counters, bits D0 and D7 of the Interrupt Status Register will be set to a 1 and the N-channel interrupt transistor will be turned on. As with a periodic interrupt, the service routine should then read the Interrupt Status Register to reset the inter- rupt transistor and, since periodic and alarm interrupts may be simultaneously enabled, determine the cause of the interrupt if necessary. Mask bits: The ICM7170 alarm interrupt compares the data in the alarm registers with the data in the real time registers, ignor- ing any registers with the mask bit set. For example, if the alarm register is set to 11-23-95 (Month-Day-Year), 10:59:00:00 (Hour-Minutes-Seconds-Hundredths), and DAY = XX (XX = masked off), the alarm will generate a single interrupt at 10:59 on November 23,1995. If the alarm register is set to 11-XX-95, 10:XX:00:00, and DAY = 2 (2 = Tuesday); the alarm will gener- ate one interrupt every minute from 10:00-10:59 on every Tuesday in November, 1995. NOTE: Masking off the 100ths of a second counter has the same effect as setting it to 00. 7. RESlSTOR IN SERIES WITH BATTERY - A 2K resistor (R2) must be placed in series with the battery backup pin of the ICM7170. The UL laboratories have requested the resistor to limit the charging and discharging current to the battery. The resistor also serves the purpose of degenerating parasitic SCR action. This SCR action may occur if an input is applied to the ICM7170, outside of its supply voltage range, while it is in the standby mode. 8. VBACKUP DIODE - Lithium batteries may explode if charged or if discharged at too high a rate. These conditions could occur if the battery was installed backwards or in the case of a gross component failure. A 1N914-type diode placed in series with the battery as shown in Figure 9 will prevent this from occurring. A resistor of 2M Ω or so should parallel the diode to keep the VBACKUP terminal from drifting toward the VSS terminal and shutting off ICM7170 I/O during normal operation. 9. SUPPLY CURRENT - ICM7170 supply current is predominantly a function of oscillator frequency and databus activity. The lower the oscillator frequency, the lower the supply current. When there is little or no activity on the data, address or control lines, the current consumption of the ICM7170 in its operational mode approaches that of the backup mode. ICM7170 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |