background image
355 AVU reinforcing mesh encapsulated within the
render. When additional reinforcement is required,
use a primary layer of the following meshes.
Heavy duty applications - 358.10 Heavy Duty Mesh.
▪
High impact applications - 358.14 High Impact Mesh.
▪
Ultra high impact applications - 358.20 Ultra High
▪
Impact Mesh. Do not apply the mesh directly to the sub-
strate and render over.
▪
▪
For high absorption substrates e.g. lightweight block,
terracotta, brickwork etc, or low absorption sub-
strates e.g. dense concrete, smooth engineering
bricks etc, apply a layer of MICRO GOBETIS 3000. For
full guidance on which substrates this is required on,
always refer to the Parex project specification.
▪
Mesh installation around openings
Reinforce the corners with 355 AVU reinforcing mesh
to all openings - minimum dimension 300 x 300 mm
before applying the main 355 AVU reinforcing mesh.
▪
NOTE: When using two layers of mesh, place the ap-
propriate primary layer of mesh into the render be-
hind the 355 AVU reinforcing mesh and butt the joints
(do not overlap). Embed the 355 AVU reinforcing
mesh over the primary mesh and overlap the joints a
minimum of 100 mm in all situations. Ensure the mesh
is fully embedded within the render coat. If an ashlar
cut is required, ensure the mesh is placed sufficiently
deep enough to avoid showing through the back face
of the ashlar cut. (Additional thickness of render will
be required for these applications).
IMPORTANT NOTE: To provide the correct level of re-
inforcement benefit, always ensure the joints of the
355 AVU reinforcing mesh and the additional layers of
mesh never meet in the same location but are posi-
tioned a minimum of 200 mm apart from each other.
Mesh installation around openings
Reinforce the corners with 355 AVU reinforcing mesh
to all openings - minimum dimension 300 x 300 mm
before applying the main 355 AVU einforcing mesh.
Mesh position within the base coat
355 AVU reinforcing mesh encapsulated within the
render. When additional reinforcement is required,
use a primary layer of the following meshes. Heavy
duty applications - 358.10 Heavy Duty Mesh. High im-
pact applications - 358.14 High Impact Mesh. Ultra
high impact applications - 358.20 Ultra High Impact
Mesh. Do not apply the mesh directly to the substrate
and render over.
LOCAL RESTRICTIONS
Please note that as a result of specific local regulations
the declared data for this product may vary from
country to country. Please consult the local Product
Data Sheet for the exact product data.
LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which
will be supplied on request.
SIKA LIMITED
Watchmead
Welwyn Garden City
Hertfordshire, AL7 1BQ
Tel: 01707 394444
Web: www.sika.co.uk
Twitter: @SikaLimited
Parex355AVUReinforcingMesh-en-GBPAREX-(01-2022)-1-1.pdf
Product Data Sheet
Parex® 355 AVU Reinforcing Mesh
January 2022, Version 01.01
021830901000000003
3 / 3



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com