  CPF81D Datasheet HTML 1Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 2Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 3Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 4Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 5Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 6Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 7Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 8Page - Endress+Hauser Group Services AG CPF81D Datasheet HTML 9Page - Endress+Hauser Group Services AG Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 12 page
background image
Orbipac CPF81D/CPF82D and CPF81/CPF82
Endress+Hauser
3
Digital sensors can store measuring system data in the sensor. These include the following:
• Manufacturing data
• Serial number
• Order code
• Date of manufacture
• Calibration data
• Calibration date
• Calibrated slope at 25 °C (77 °F) (CPF81D)
• Calibrated zero point at 25 °C (77 °F) (CPF81D)
• Calibrated offset (CPF82D, ORP mV measuring mode)
• Slope as % (CPF82D, ORP % measuring mode)
• Temperature offset
• Number of calibrations
• Serial number of the transmitter used for the last calibration
• Calibration database (stores the last 8 calibrations in the Memosens head)
• Application data
• Temperature application range
• pH application range (CPF81D)
• ORP application range (CPF82D)
• Date of first commissioning
• Maximum temperature value
• Operating hours at temperatures above 80 °C (176 °F) and 100 °C (212 °F)
• Operating hours at very low and very high pH values (Nernst voltage below -300 mV, above
+300 mV)
Reliability
Dependability
Easy handling
Sensors with Memosens technology have integrated electronics that store calibration data and other
information (e.g. total hours of operation or operating hours under extreme measuring conditions).
Once the sensor has been connected, the sensor data are transferred automatically to the transmitter
and used to calculate the current measured value. As the calibration data are stored in the sensor,
the sensor can be calibrated and adjusted independently of the measuring point. The result:
• Easy calibration in the measuring lab under optimum external conditions increases the quality of
the calibration.
• Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the
availability of the measuring point.
• Thanks to the availability of the sensor data, maintenance intervals can be accurately defined and
predictive maintenance is possible.
• The sensor history can be documented on external data carriers and in evaluation programs.
• Thus, the current application of the sensors can be made to depend on their previous history.
Interference immunity
Data security thanks to digital data transmission
Memosens technology digitizes the measured values in the sensor and transmits the data to the
transmitter via a non-contact connection that is free from potential interference. The result:
• Automatic error message if sensor fails or connection between sensor and transmitter is
interrupted
• Immediate error detection increases measuring point availability
Safety
Maximum process safety
With inductive transmission of the measured value using a non-contact connection, Memosens
guarantees maximum process safety and offers the following benefits:
• All problems caused by moisture are eliminated:
• Plug-in connection free from corrosion
• Measured values cannot be distorted by moisture
• Can even be connected under water
• The transmitter is galvanically decoupled from the medium. Issues concerning "symmetrical high-
impedance" or "asymmetry" or an impedance converter are a thing of the past.
• EMC safety is guaranteed by screening measures for the digital transmission of measured values.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com