Electronic Components Datasheet Search
  English  ▼

X  

EE75 Datasheet(PDF) 8 Page - E+E Elektronik Ges.m.b.H

Part # EE75
Description  Highly Accurate Air / Gas Velocity Sensor for Industrial Applications
PDF  9 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  EPLUSE [E+E Elektronik Ges.m.b.H]
Direct Link  https://www.epluse.com/
Logo EPLUSE - E+E Elektronik Ges.m.b.H

EE75 Datasheet(HTML) 8 Page - E+E Elektronik Ges.m.b.H

  EE75 Datasheet HTML 1Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 2Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 3Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 4Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 5Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 6Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 7Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 8Page - E+E Elektronik Ges.m.b.H EE75 Datasheet HTML 9Page - E+E Elektronik Ges.m.b.H  
Zoom Inzoom in Zoom Outzoom out
 8 / 9 page
background image
Datasheet EE75
v2.5 / Modification rights reserved | 8
Ordering Example
EE75-T26A6HV30L400K10D2PA29SAL-20SAH120SBH20
Feature
Code
Description
Type
T26
Remote Probe, pressure tight, 10 bar
Output
A6
4 - 20 mA
Measuring Range
HV30
0...40 m/s (0...8 000 ft/min)
Probe length
L400
400 mm (15.75")
Probe cable length
K10
10 m (32.8 ft)
Display
D2
Display with backlight
Process connection
PA29
G 1/2" ISO - cut-in fitting, Ø8 mm (0.31")
Electrical connection
No code
Cable glands
Output 1 measurand
No code
Temperature T [°C]
Output 1 scaling low
SAL-20
-20 °C
Output 1 scaling high
SAH120
120 °C
Output 2 measurand
No code
Air velocity v [m/s]
Output 2 scaling low
No code
0 m/s
Output 2 scaling high
SBH20
20 m/s
Medium
No code
Air
EE75-T2A6HV26L600E4MA21SAH2000MB90SBH2000FU2DC200
Feature
Code
Description
Type
T2
Duct mount
Output
A6
4 - 20 mA
Measuring Range
HV26
0...10 m/s (0...2 000 ft/min)
Probe length
L600
600 mm (23.62")
Probe cable length
No code
Not applicable
Display
D2
Display with backlight
Electrical connection
E4
1 x plug for power supply and outputs
Output 1 measurand
MA21
Air velocity v [ft/min]
Output 1 scaling low
No code
0 ft/min
Output 1 scaling high
SAH2000
2000 ft/min
Output 2 measurand
MB90
Volume flow V' [ft3/min]
Output 2 scaling low
No code
0 ft3/min
Output 2 scaling high
SBH2000
2000 ft3/min
Medium
FU2
Nitrogen
Duct cross section
DC200
200 inch2



Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com